Application of low/high Temperature Test Chamber for high-low temperature resistance test of oil pump

Abstract: 高低温试验箱用于测试油泵在极端温度下的性能和可靠性。试验评估油泵在高温和低温环境中的工作能力,包括流量、压力、转速等关键参数,并检查其材料和结构的耐久性,如密封性和耐磨性。试验步骤包括检查试验设备、安装油泵样品、设置温度范围并进行升降温循环、记录性能变化,并在测试结束后对油泵进行外观和功能评估。通过这些测试,确保油泵在各种温度条件下的稳定性和长期可靠性。

An oil pump is a common mechanical device used to deliver lubricating oil or fuel in mechanical equipment such as engines. Since the oil pump will be exposed to different temperature environments, such as high temperature or low temperature environment, high-low temperature resistance tests are required to ensure the performance and reliability of the oil pump at various temperatures. This test can test the working ability of the oil pump at different temperatures, such as flow, pressure, speed, etc., so as to ensure the normal operation and long-term stability of the oil pump. In addition, the high-low temperature resistance test can also test the durability and stability of the material and structure of the oil pump, such as sealing, wear resistance, etc., so as to ensure that the oil pump will not fail or be damaged during long-term use.

Application diagram 1 of high-low Temperature Test Chamber for high-low temperature resistance test of oil pump

experiment method

The high-low Temperature Test Chamber can be used for high-low temperature resistance tests of oil pumps to test the performance and reliability of oil pumps in high-low temperature environments. The following are the test steps of the high-low Temperature Test Chamber in the high-low temperature resistance test of the oil pump:

  1. Preparation: Check whether the Test Chamber and temperature controller are working normally, and set the temperature range and heating and cooling rate of the Test Chamber according to the test requirements. Prepare an oil pump sample, noting its size and location.

  2. Sample installation: place the sample of the oil pump to be tested in the test box, and fix the position and direction.

  3. Test operation: Turn on the Test Chamber and temperature controller, and set the temperature range and heating and cooling rate of the Test Chamber. Raise the temperature of the Test Chamber to the set temperature range, keep it for a period of time, and then cool down to the set temperature. During the test, record the temperature change inside the Test Chamber, and pay attention to observe the performance change of the oil pump sample.

  4. Evaluation of test results: After the test, take out the oil pump sample and observe whether there is deformation or cracking in its appearance. At the same time, the output flow, pressure and other parameters of the oil pump are tested and evaluated. Through the evaluation of the test results, the tolerance and stability of the oil pump in the high-low temperature environment can be judged.

North and South Chao reminds you: the oil pump should be cleaned and dried before the test, so as not to affect the test results. During the test, the temperature range and heating and cooling rate inside the Test Chamber should be strictly controlled to ensure the accuracy and reliability of the test. At the same time, the Test Chamber should be cleaned and maintained after the test to prolong its service life.