Low/high Temperature Test Chamber testing shock absorber high-low temperature resistance

Abstract: 高低温试验箱用于测试减振器在极端温度环境下的耐久性和稳定性。减振器广泛应用于机械设备中,需要在高低温条件下验证其性能。试验过程包括将减振器放入高低温试验箱内,设置适当的温度范围和变化速率,进行高低温交替循环测试。测试期间记录减振器在高温和低温环境下的性能数据,测试时间根据要求可长达数小时至数天。测试结束后,分析数据以评估减振器的性能和寿命,确保其符合设计标准。此过程有助于确保减振器在实际使用中的可靠性和稳定性,并为生产商提供改进依据。

The high-low Temperature Test Chamber is a kind of equipment specially used to simulate extreme temperature environment, which can test the durability and stability of various materials and products under high-low temperature environment.

A shock absorber is a device used to reduce mechanical vibration and noise, and is widely used in mechanical equipment such as automobiles, trains, and machine tools. In practical applications, the shock absorber needs to withstand the effects of different temperatures, and it needs to pass the durability test under the alternating action of high-low temperature, so as to ensure its performance and life in different environments. High-low Temperature Test Chambers can provide reliable conditions for this test.

High-low Temperature Test Chamber to test the high-low temperature resistance of the shock absorber with picture 1

experiment procedure

  1. Place the shock absorber in the high-low Temperature Test Chamber, and make sure there are no other objects around it.

  2. Set the temperature range and change rate of the high-low Temperature Test Chamber, generally according to the standard test requirements.

  3. Open the high-low Temperature Test Chamber and start the high-low temperature cycle test.

  4. In high temperature and low temperature environments, the shock absorber is continuously tested respectively. The general test time ranges from several hours to several days, and the specific time is determined according to the test requirements.

  5. According to the test requirements, gradually increase or decrease the temperature in the high-low Temperature Test Chamber, and record the performance and life data of the shock absorber at each temperature point.

  6. After the test, analyze and evaluate the test data to judge whether the shock absorber meets the design requirements.

NBCHAO reminds you: During the high-low temperature test of the shock absorber, it needs to be tested specifically, including its response to vibration, pressure, etc., so as to ensure its reliability and stability in actual use. At the same time, after the test, it is necessary to analyze and evaluate the relevant data, and report the test results, so that the manufacturer can make further improvement and optimization.

Products required
Relevant knowledge