The operating procedures of the laboratory grinding and dispersing machine can be carried out according to the following steps:
Preparation:
Make sure that the power supply of the laboratory grinding and dispersing machine is connected normally, and check whether the safety devices of the equipment are in good condition.
Check the type and quality of the abrasive medium (such as abrasive beads) to ensure that it meets the experimental requirements.
Prepare samples that need to be ground and dispersed, and prepare corresponding solvents or media as needed.
Device preparation:
Open the lid or top cover of the Grinder disperser and install the Grinder disperser, such as a Grinder tank or Grinder chamber, on the equipment.
As needed, place the abrasive medium (eg abrasive beads) into the abrasive dispersion unit and ensure that its quantity and specification meet the requirements.
Sample Handling:
The sample to be ground and dispersed is added to the grinding and dispersing device, and a corresponding solvent or medium is added as needed.
Adjust the temperature, pressure or other parameters of the grinding and dispersing device as needed.
Start operation:
Turn on the power switch of the grinding disperser and start the equipment.
According to the operation interface or control panel of the equipment, set the grinding dispersion time, speed and other relevant parameters.
Wait for the equipment to reach the set working state and start the grinding and dispersing process.
Monitor and adjust:
During the grinding and dispersing process, the working status of the equipment is regularly monitored to ensure its normal operation.
According to the needs, adjust the grinding dispersion time, speed or other parameters according to the actual situation to achieve the required grinding effect.
End operation:
After the grinding and dispersing is completed, turn off the power switch of the grinding and dispersing machine.
The abrasive dispersion unit is removed from the equipment for cleaning and maintenance.
Clean the work area of the laboratory Grinder disperser to ensure a clean environment around the equipment.
It should be noted that the specific operating procedures may vary from laboratory to laboratory and equipment. Before operating the laboratory Grinder disperser, it is recommended to read the operation manual of the equipment carefully and adjust the operation steps according to the actual situation. In addition, follow the laboratory safe operation code to ensure personal safety and the normal operation of laboratory equipment.