Detection voltage schedule

Anticorrosive materialsThickness of the anti-corrosion layer
(mm)
Detect voltage
(KV)
remark
Epoxy Coal Leaching Book0.24~5KV or customizedIf there is a standard, it should be implemented according to the standard
0.4
0.6
0.8
Petroleum asphalt211
315
5.518
720
924
Polyethylene tapeConverted according to: 3249TC-V formula
V: Voltage TC: Thickness of anti-corrosion layer
According to SY4014-92 acceptance specification standard
Glass-linedAccording to experience, the detection voltage is generally 8KV~20KV
Other anticorrosive materialsDepending on the design of the design department, the voltage or the insulation properties of the material itself are tested.

Coating thickness vs. reference voltage comparison table

Coating thickness
(μm)
Reference voltage
(KV)
Coating thickness
(μm)
Reference voltage
(KV)
500.712505.5
100115006.3
1501.220008
2001.525009.6
2501.7300011.1
30020350012.6
3502.2400014.1
4002.4500017.1
5002.9600020.1
6003.3800025.7
80041000030.1
10004.7* The above is for reference only