The article "Control of Fabric Heat Setting Temperature" mainly discusses the measurement and control of fabric temperature, providing a part of the basis for optimizing the heat setting process, ensuring product quality and reducing energy consumption. In the article, the author introduces the paper temperature measurement method, the contact non-continuous temperature measurement method, the contact continuous temperature measurement method and the non-contact continuous temperature measurement method, and focuses on the analysis of the non-contact continuous temperature measurement method . Two methods: infrared radiation temperature measurement method, thermal convection zero value balance temperature measurement method.
get conclusion
1) Using the infrared radiation temperature measurement method, the speed of the machine can be adjusted according to the reading of the fabric temperature. In most cases, the speed of the machine can be increased by 15~30%, thus greatly shortening the heat setting time and improving production efficiency. In addition, the heating stage of heat setting is controlled by measuring the temperature of the fabric, which can ensure that the fabric is fully dried and set without wasting energy and time due to excessive temperature and long reaction time.
2) Using the thermal convection zero balance method is especially suitable for measuring the temperature of the fabric in the environment of the drying room, and effectively monitoring the heat setting machine. By directly controlling the temperature of the fabric, good effects of improving product quality and reducing energy consumption are achieved.