Back
Knowledge

A list of imported testing instruments for paint film testing

In the paint industry, under normal circumstances, the dry paint film needs to be tested for various physical properties to verify the quality of the product. This article is a selection list of instruments for testing the physical properties of dry paint films, including color measurement, thickness measurement, roughness testing, orange peel, and gloss testing. This list is all imported instrument brands familiar in the industry, which can be provided to high-end users as a reference for model selection.

Physical property testing instrument - thickness
A list of imported testing instruments for paint film testing with Figure 1Defelsko B Advanced 200B3-E Ultrasonic Thickness Gauge
Specification parameters: measuring range 13~1000μm, probe style split probe, pipe measurement lower limit 13μm, measurement error ±(3%H+2)μm, display resolution 1μm, unit system μm/mils, storage capacity 100,000 measured values, 1000 groups, statistical function average value, standard deviation, minimum/maximum thickness and number of readings, meet the standards ASTM D6132, ISO 2808, display color LCD display, operating language Chinese, English, data interface USB, application software available, Power supply 3*7 batteries, host size 135*61*28mm, weight 140g (excluding batteries), polymer coating for wood, plastic, etc.
Physical performance testing instrument - color
A list of imported testing instruments for paint film testing with Figure 2Konica Minolta CM-512m3A Spectrophotometer
Specification parameters: Illumination method Illumination: 25°, 45°, 75°, sensor silicon photodiode array, measurement range 400nm~700nm, measurement light source pulse xenon lamp*3, measurement aperture Φ12mm/Φ20mm, after repeated whiteboard calibration, it takes 10 seconds Measure the white calibration plate 30 times at intervals, operating language Simplified Chinese, English, data interface RS-232C, observation angle CIE 2°/10°, observation light source A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, data storage 440 groups (all standard and sample data), power supply voltage 4 AA alkaline or Ni-MH batteries, AC adapter, display mode chromaticity value: L*a*b*, L*C*h; Color difference value: Δ(L*a*b*), Δ(L*C*h*), ΔE*ab CMC (l:c), ΔE00 (CIE 2000), operating environment 0°C~40°C, Relative humidity below 85% (35°C), no condensation, storage environment -20~45°C, relative humidity below 85% (35°C), no condensation, external dimensions 164*115*257mm, weight approx. 1.4kg (without battery), wavelength interval 20nm, reflectance measurement range 25°: 0~300%, 45° and 75°: 0~200% resolution: 0.01%
Physical Property Testing Instrument - Gloss
A list of imported testing instruments for paint film testing with Figure 3BYK BYK 4564 Micro Triangular Gloss Meter
Specification parameters: measurement angle 20°/60°/85°, measurement range 0~100GU, repeatability ±0.2GU, reproducibility ±0.5GU, measurement spot 10*10mm; 9*15mm; 5*38mm, measurement mode basic measurement , statistical measurement, difference measurement, continuous measurement, meet the standards ISO 2813, ASTM D 523, DIN 67530, ISO2178, ISO2360, ISO2808, ASTM B499, ASTM D 1400, data interface USB data interface, Bluetooth, data storage 999 readings, The operating language is English, German, the overall size is 155*73*48mm, the weight is 400g, the accuracy is ± (1.5 μm+2% of the measured value), the substrate Fe: magnetic; NFe: non-magnetic
Physical property testing instrument - roughness
A list of imported testing instruments for paint film testing with Figure 4Mitutoyo SJ-210 (4mN) Standard Roughness Meter
Specification parameters: Measuring range-X axis 16.0mm, Measuring range-Detector range 360µm, Measuring range-Detector resolution 0.02µm|0.006µm|0.002µm, Measuring speed 0.25mm/s|0.5mm/s|0.75 mm/s, Measuring force/stylus tip shape 90º, 5µmR, guide head pressure <400mN, applicable standard JIS1982/JIS1994/JIS2001/ISO1997/ANSI/VDA, evaluate the original contour, roughness curve, DF curve, roughness motif Curves, evaluation parameters Ra, Rc, Ry, Rz, Rq, Rt, Rmax, Rp, Rv, R3z, Rsk, Rku, Rc, RPc, Rsm, etc., support user-defined, analysis charts support curves/amplitude distribution curves, filtering Gaussian, 2CR75, PC75, cut-off wavelength λc: 0.08, 0.25, 0.8, 2.5mm; λs2.5, 8µm, sampling length 0.08, 0.25, 0.8, 2.5mm, sampling number × 1, × 2, × 3, × 4 ,×5,×6,×7,×8,×9,×10, arbitrary length (0.3to16.0mm: 0.01mm interval), screen display LCD: 36.7×48.9mm, display language 16 languages ​​(including Chinese and English ), Calculation result display Vertical display: 1 segment/3 segment/zoom in Horizontal display: 1 segment/4 segment/zoom in (horizontal display can be switched left and right), GO/NG interpretation of maximum value, 16% value, standard deviation, built-in data storage Memory: Measuring conditions (10 pieces), optional memory card, automatic calibration of calibration input value / multiple measurement (maximum 5 times) average calibration method, power supply built-in battery (Ni-MH rechargeable battery) / AC adapter charging Time: about 4 hours (may vary depending on the ambient temperature), battery life about 1000 measurements, weight about 500g (display unit, drive unit, standard Detector), external dimension calculation display unit 52.1×65.8×160mm (sliding cover closed, the Detector is not installed); drive part 115×23×26mm (including Detector), series type standard driver type
Other testing instruments - other
A list of imported testing instruments for paint film testing with Figure 5BYK BYK 4840 Orange Peel Tester
Specifications: high gloss to medium gloss surface du < 65, linear range, wavelength spectrum du: <0.1 mmWa: 0.1 to 0.3 mmWb: 0.3 to 1 mmWc: 1 to 3 mmWd: 3 to 10 mmWe: 10 to 30 mm, repeat Reproducibility du < 40: 4% or > 0.4du > 40: 6% or > 0.6, Reproducibility du < 40: 6% or > 0.6du > 40: 8% or > 0.8, workpiece radius of curvature > 500 mm, min. Sample size 35 mm x 150 mm, scanning range 5 / 10 / 20 cm, resolution 375 points/cm, memory 1500 readings, interface USB port, languages ​​English, French, German, Italian, Japanese, Portuguese, Spanish , light source laser diode, LED and IR-SLED, laser energy < 1 mw (laser class 2), volume 150 x 110 x 55 mm (5.9 x 4.3 x 2.2 in.), weight 650 g (1.5 lbs), power supply available Rechargeable battery pack or 3 small AA batteries (alkaline or rechargeable), approx. 1000 measurements, temperature range operating temperature: +10 °C to 40 °C (+ 50 °F to 104 °F), storage Temperature 0°C to 60°C (+32°F to 140°F), relative humidity up to 85% at 35°C (95°F), non-condensing