Calibration and use of LX-A Shore Hardness Tester

Abstract: 本文介绍了LX-A邵氏硬度计的校准和使用方法。校准过程中,首先将校准块放在平面上,将硬度计测试头对准校准量块上数字“25”的孔位置,平稳按压硬度计,并与校准量块保持平行,确保指针读数为25(±0.5HA)以完成校准。接着,将测试头对准数字“75”的位置,确保读数为75(±0.5HA)以完成第二步校准。使用时,将试样置于平面上,保持硬度计与试样表面平行并无振动,压足与试样紧密接触。根据不同材料(硫化橡胶、热塑料橡胶等)的测试要求,分别在3秒或15秒后读取硬度值。在试样表面至少6mm处的不同位置测量5次,并取其平均值以获得准确的硬度值。

Calibration method of LX-A Shore Hardness Tester

Calibration and usage of LX-A Shore Hardness Tester with Figure 1

Step 1: Place the calibration block on a solid surface.

Step 2: Align the test head of the Hardness Tester with the hole corresponding to the number "25" of the calibration gauge block , press the Hardness Tester smoothly, and keep it parallel to the calibration gauge block. Hold for 3 seconds , the pointer reading is 25 (±0.5HA), then the calibration is successful.

Step 3: Use the same method as Step 2 to align the test head at the position of the number '75" on the test gauge block. If the reading is 75 (±0.5HA), the calibration is successful.

Instructions

Place the sample on a solid plane, hold the Hardness Tester, press the needle at least 12mm away from the edge of the test block, press the presser foot on the sample smoothly without any vibration, and keep the presser foot parallel to the surface of the sample, Press the needle vertically into the sample. The force applied should be sufficient to make the presser foot and the sample come into close contact, and the reading should be taken at the specified time, 3 seconds for vulcanized rubber or unknown type rubber, and 15 seconds for thermoplastic rubber; if other sample time is used, it should be stated in the test report illustrate. Measure the hardness value 5 times at different positions at least 6mm apart from the sample, and take the average value.