What performance testing should be done for painting in building reflection and heat insulation? How to meet the standard?

Abstract: 本文介绍了GB/T 25261—2018标准对建筑反射隔热中涂漆的性能检测要求。该标准适用于由树脂、颜填料等制成的均一颜色涂漆,分为1级和2级两种隔热效果,以及普通型(P型)和弹性型(T型)两种基本性能。检测项目包括:导热系数(1级≤0.08m*k,2级≤0.15m*k);在容器中状态要求均匀无硬块;低温稳定性需经三次循环测试;施工性需无刷涂障碍;干燥时间表干≤2小时;涂膜外观应无明显缺陷;耐碱性和耐水性测试需无严重涂膜病态现象;涂层耐温变性需经三次循环测试无异常;粘结强度≥0.4MPa;弹性型涂料的拉伸强度需≥1.0MPa,断裂伸长率≥80%,低温柔性结果需无裂纹。

GB/T 25261-2018 is applicable to uniform colors made of resins, pigments and fillers, additives, functional materials, etc. Today we will introduce the provisions of this standard for painting in building reflective insulation.

Before introducing it, we must first understand its classification. We divide it into grade 1 and grade 2 according to the heat insulation effect; according to the basic performance, it is divided into ordinary type (P type) and elastic type (T type).

Item detection

functional requirements

Thermal conductivity: ≤0.08m*k for class 1 samples, >0.08m*k for class 2 samples, ≤0.15m*kWhat performance testing should be done for painting in building reflective insulation?  How to meet the standard?  Picture 1


Basic performance requirements

1. State in the container: If the P-type and T-type are in a uniform state after stirring, and there is no hard lump, it is considered to be up to standard.

2. Low temperature stability: carry out three cycle tests, if the result is no deterioration, it is regarded as up to standard.

3. Constructability: If the result is "no obstacle for brushing", it is regarded as up to standard.

4. Drying time: if the surface of the sample is dry ≤ 2 hours, it is considered up to the standard.

5. Appearance of the coating film: observe the coating film visually. If the surface is smooth and there is no significant shrinkage cavity, cracking and other coating film pathological phenomena, it is rated as "normal".

6. Alkali resistance: Soak in the test solution for 48 hours, if there is no abnormal phenomenon of coating film such as foaming and falling powder, and slight discoloration is allowed, it is considered to meet the standard.

7. Water resistance: immersion in water for 96 hours, if there is no abnormal phenomenon of coating film such as foaming and falling powder, it is considered to meet the standard.

8. Coating resistance to temperature denaturation: carry out three cycle tests, if there is no abnormality in the result, it is regarded as up to standard.

9. Adhesive strength: if the sample is ≥0.4MPa, it is regarded as up to standard.

10. Tensile strength: If the T type is ≥1.0MPa, it is considered to be up to standard.

11. Elongation at break: If the T type is ≥ 80%, it is regarded as up to standard.

12. Low-temperature flexibility: If the T-shaped result is 0°C and the diameter is 4mm without cracks, it is considered up to the standard.