Talc powder is a powdery item. If you want to test the color, you need to choose some instruments that can support powder color measurement, or you can use a Colorimeter with powder test components for testing. So which Colorimeters are suitable for the color measurement of talcum powder?
This article selects some Spectrophotometer s suitable for testing talcum powder for your reference. For more detailed selection, please consult North and South Tide Technology. First look at the table below:
| Physical Properties - Color | |
![]() | Color spectrum CS-280 spectroColorimeter |
| Specification parameters: illumination mode di/8 (scattered light source, 8 degree observation angle) SCI (conforming to CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition c standard), integrating sphere size Φ40mm, illumination Light source CLED, sensor array sensor, wavelength range 400~700nm, spectral half bandwidth 10nm, measurement time 2s, measurement aperture Φ11mm, chromaticity value repeatability standard deviation ΔE*ab 0.08, observation angle CIE 2°/10°, observation light source A , C, D50, D65, display mode sample chromaticity value (L*a*b, L*C*h), color difference value, pass judgment, color deviation, average value, generate test report, spectrogram, color difference formula ΔE *ab, ΔE*CH, color space CIE-L*a*b, L*C*h, chromaticity index staining fastness, color fastness, data storage 20,000 test data, light source life 5 years 1.5 million times, Display full color true color screen, language Chinese, English, data interface USB2.0, operating temperature 5~45°C, relative humidity 80% or lower (at 35°C), no moisture condensation, storage environment_-25 ℃ to 55℃, relative humidity 80% or lower (at 35℃), no moisture condensation, power supply voltage rechargeable lithium battery 8.4V/2000mAh, dedicated adapter DC12V, external dimensions 77*86*210mm, weight about 550g , the color matching system cannot be matched, and the UV light source does not contain UV light source | |
![]() | Color Spectrum CS-520 Portable Spectrophotometer |
| Specification parameters: measurement condition d/8 (diffuse illumination, 8° direction reception), SCI (including specular reflection light), SCE (specular reflection light not included), observation light source LED, measurement parameter spectral reflectance, CIE-Lab, CIE -LCh, HunterLab, CIE-Luv, XYZ, Yxy, RGB, color difference, whiteness, yellowness, blackness, staining fastness, color fastness, Tint, color density CMYK (A, T, E, M), Metamerism Index Milm, Munsell, Hiding Power, Strength, Observation Light Source A, B, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, U35, DLF, NBF, TL83, TL84, observation angle CIE 2°/10°, sensor 256 pixel CMOS sensor, calibration method automatic induction calibration, wavelength interval 10nm, wavelength range 400~700nm, reflectance measurement range 0~200%, reflectivity resolution 0.01%, integrating sphere size Φ40mm, spectral reflectance repeatability standard deviation less than 0.1%, measuring aperture MAV:Φ8mm/Φ11mm MAV:Φ4mm/Φ6mm MINI: 1*3mm, inter-unit difference ΔE*ab<0.2, measurement time about 1s, data storage APP mass storage, battery life can be continuously measured 8000 times on a single charge, 3.7V/3000mAh, display IPS full-color screen, 2.4 inches, Data interface USB, Bluetooth, light source life of 10 years and 1 million times, language Simplified Chinese, English, software support Andriod, IOS, Windows, whether it is qualified for the first-level measurement, the camera has a viewfinder positioning, and the overall size is 77.8*53.2*185.7mm , weight about 300g, maximum repeatability of chromaticity value: dE*ab< 0.04; average value: dE*ab< 0.03; standard deviation value is less than ΔE*ab< 0.02 | |
![]() | Color Spectrum CS-650A Xenon Arc Spectrophotometer |
| Specifications:Illumination mode Observer angle: 2°/10° Illumination: d/8 (scattered light source, 8 degree observation angle), SCI (including specular reflection component)/SCE (excluding specular reflection component) synchronous measurement function. , sensor dual optical path array sensor, measurement range 0~200%, illumination source pulsed xenon lamp, measurement time 2s, measurement aperture Φ10mm, spectral reflectance repeatability standard deviation within 0.08%, data interface USB, Bluetooth (customizable), observation light source A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30.DLF,NBF,TL83,TL84.U35, Color difference formula ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*94, ΔE*00, ΔEab(Hunter), 555 color tone categories, data Store 20,000 test data, display mode spectrogram/data, sample chromaticity value, color difference value, pass/fail result, color deviation, display measurement area, color simulation of historical data, manually input standard sample, generate test report, operate Environment 0-45°C, relative humidity 80% or lower (at 35°C), no moisture condensation, storage environment -25~55°C, relative humidity 80% or lower (at 35°C), anhydrous Condensation, external dimensions 181*73*112mm, weight about 550g (excluding batteries), integrating sphere size Φ40mm, wavelength range 360~740nm, wavelength interval 10nm, spectral half bandwidth 5nm, resolution 0.01%, measurement time about 2 seconds , Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, reflectivity, Hunter-lab, Munsell MI, CMYK.RGB.HSB, chromaticity index WI, YI, TI, metamerism index MI, staining fastness, color fastness, strength, opacity, tinting strength, strength, ISO brightness, 8 gloss, A density, T density, M density, E density, difference between platforms ΔE*ab<0.2, battery life can be recharged, continuous measurement 10000 times, 7.4V/6000mAh, full-color true color display screen, color matching system can be equipped, UV light source UV light source, chromaticity value repeatability ΔE*ab 0.02, max. value 0.04 | |
![]() | Color spectrum CS-390 three-angle Spectrophotometer |
| Specification parameters: illumination mode 45°, measurement angle color angle: 15°, 45°, 110°, measurement parameters color parameters: L*a*b*, dE*ab, wavelength range 400~700nm, spectral interval 10nm, measurement range 0~500%, resolution 0.01%, lighting source LED, measurement time less than 2s, chromaticity value repeatability dE≤0.05, inter-stage difference dE≤0.5, measurement area diameter 17mm, observation angle CIE 2°/10°, illumination Light sources A, C, D50, D65, F2, F7, F11 & F12, data interface USB, external dimensions about 145*58*99mm, weight about 500g, power supply voltage 3.7V/3000mAh rechargeable lithium battery, operating temperature 0-40 ℃, storage environment -20~50℃ | |
![]() | Color Spectrum CS-392 Three-angle Spectrophotometer |
| Specification parameters: illumination mode 45°, measurement angle color angle: 15°, 45°, 110°; particle angle: integrating sphere diffusion, measurement parameter color parameter: L*a*b*,dE*ab; particle parameter: particle Grade (G), wavelength range 400~700nm, spectral interval 10nm, measurement range 0~500%, resolution 0.01%, lighting source LED, measurement time less than 6s, chromaticity value repeatability dE≤0.05, inter-station difference dE≤ 0.5, measuring area diameter 17mm, observation angle CIE 2°/10°, illumination sources A, C, D50, D65, F2, F7, F11 & F12, data interface USB, overall size about 145*58*99mm, weight about 500g , power supply voltage 3.7V/3000mAh rechargeable lithium battery, operating temperature 0-40℃, storage environment -20~50℃ | |
![]() | Color Spectrum CS-820N Spectrophotometer |
| Specifications:Illumination method Reflection: d/8 (diffuse illumination, receiving in 8° direction) SCI (including specular reflection light) / SCE (specular reflection light not included) simultaneous measurement; Transmission: d/0 (diffuse illumination, receiving in vertical direction) , sensor silicon photodiode array, observation light source pulsed xenon lamp*4, measurement time SCI or SCE mode <2s, SCI+SCE simultaneous measurement <4s, measurement aperture reflection: XLAV Φ25.4mm, LAVΦ15mm, MAVΦ8mm, SAVΦ3mm (user can customize caliber, caliber switching automatic identification); transmission: Φ17mm, spectral reflectance repeatability XLAV spectral reflectance/transmittance: standard deviation within 0.1% XLAV, operating language Chinese, English, data interface USB, RS-232, viewing angle CIE 2 °/10°, observation light source A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, DLF, NBF , TL83, TL84, color difference formula ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔEab(Hunter), 555 color classification, data storage 10 million data, power supply voltage 12V /2.5A, operating environment 5~40°C, no condensation below 80% relative humidity (at 35°C), storage environment -20~45°C, no condensation below 80% relative humidity (at 35°C), appearance Size 430*240*260mm, spectroscopic concave grating, integrating sphere size Φ152mm, wavelength range 360~780nm, wavelength interval 10nm, spectral half bandwidth 5nm, reflectivity measurement range 0~200%, UV switching includes UV, 400nm cut-off, 420nm Cut-off, 460nm cut-off, transmission measurement specifications, sample width and height: unlimited, thickness: ≤50mm, inter-stage difference ΔE*ab<0.15 (XLAV), display mode spectral data, spectrogram, chromaticity data, color difference data, color difference diagram , pass/fail judgment, simulated color, color evaluation, haze, liquid chromaticity, color deviation, color space L*a*b, L*C*h, Hunter Lab, Yxy, XYZ, display 7-inch touch screen, Android operating system, albedo resolution 0.01%, chromaticity value repeatability standard deviation ΔE*ab within 0.015 | |
![]() | Color Spectrum CS-821N Spectrophotometer |
| Specifications:Illumination/Measurement Conditions 1 Reflection: d/8 (diffuse illumination, reception in 8° direction); transmission: d/0 (diffuse illumination, reception in vertical direction), sensor silicon photodiode array, light splitting concave grating, integrating sphere size Φ152mm, wavelength range 360~780nm, wavelength interval 10nm, spectral half bandwidth 5nm, reflectance measurement range 0~200%, illumination source pulse xenon lamp and LED, ultraviolet measurement includes UV, 400nm cutoff, 420nm cutoff, 460nm cutoff, measurement time SCI Or SCE mode <2s, SCI+SCE simultaneous measurement <4s, transmission measurement specification sample width and height: unlimited, thickness: ≤50mm, long-term repeatability XLAV chromaticity value: standard deviation ΔE*ab within 0.015 (20℃±10 ℃ any temperature change, measure the white calibration plate every hour within 24 hours), spectral reflectance repeatability XLAV spectral reflectance/transmittance: standard deviation within 0.1%, repeatability 2XLAV chromaticity value: standard deviation ΔE*ab within 0.015 (After the instrument is calibrated, measure the white calibration plate 30 times at intervals of 10 seconds), inter-stage difference ΔE*ab<0.15 (XLAV), observation angle CIE 2°/10°, observation light sources A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, DLF, NBF, TL83, TL84, language Simplified Chinese, English, Traditional Chinese, Russian, Spanish English, Portuguese, Japanese, Thai, Korean, German, French, Polish, display mode spectral data, spectrogram, chromaticity data, color difference data, color difference graph, pass/fail judgment, simulated color, color evaluation, haze , liquid chromaticity, color bias, color space L*a*b, L*C*h, Hunter Lab, Yxy, XYZ, chromaticity index WI, YI, TI, metamerism index MI, stain fastness, color change Fastness, strength, opacity, strength, ISO brightness, R457, A density, T density, E density, M density, APHA, Hazen, Pt-Co (platinum-cobalt index), Gardner (Gardner index), Saybolt (Seibert index), Astm color, haze, total transmittance, color difference formula ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc,ΔE*94, ΔE*00, ΔEab(Hunter), 555 color categories, storage space 8GB, screen 7-inch capacitive touch screen, operating system Android, power supply voltage 12V/3A, operating environment 5~40°C, relative humidity 80%( No condensation below 35°C, storage environment -20~45°C, no condensation below 80% relative humidity (35°C), data interface RS-232, USB, USB-B, reflectivity resolution 0.01% | |
![]() | Color Spectrum CS-826 Spectrophotometer |
| Specifications:Illumination/measurement conditions Reflection: d/8 (diffuse illumination, receiving in 8° direction); transmission: d/0 (diffuse illumination, receiving in vertical direction), sensor silicon photodiode array, light-splitting concave grating, integrating sphere size Φ152mm , wavelength range 360~780nm, wavelength interval 10nm, spectral half bandwidth 5nm, reflectance measurement range 0~200%, illumination source pulse xenon lamp and LED, ultraviolet measurement includes UV, 400nm cutoff, 420nm cutoff, 460nm cutoff, measurement time SCI or SCE mode <2s, SCI+SCE simultaneous measurement <4s, transmission measurement specifications sample width and height: unlimited, thickness: ≤50mm, long-term repeatability XLAV chromaticity value: standard deviation ΔE*ab0.01 or less, maximum value ΔE* ab within 0.02), spectral reflectance repeatability XLAV spectral reflectance/transmittance: standard deviation within 0.1%, inter-stage difference ΔE*ab<0.1(XLAV), observation angle CIE 2°/10°, observation light source A, C ,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84, Language Simplified Chinese, English , Traditional Chinese, Russian, Spanish, Portuguese, Japanese, Thai, Korean, German, French, Polish, display mode spectral data, spectral graph, chromaticity data, color difference data, color difference graph, pass/fail judgment, simulation Color, color evaluation, haze, liquid chromaticity, color bias, color space L*a*b, L*C*h, Hunter Lab, Yxy, XYZ, chromaticity index WI, YI, TI, metamerism index MI , color fastness, color fastness, strength, opacity, strength, ISO brightness, R457, A density, T density, E density, M density, APHA, Hazen, Pt-Co (platinum cobalt index), Gardner ( Gardner index), Saybolt (Saibert index), Astm color, haze, total transmittance, color difference formula ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00 ,ΔEab(Hunter),555 color categories, storage space 8GB, screen 7-inch capacitive touch screen, operating system Android, power supply voltage 12V/3A, operating environment 5-40°C, relative humidity below 80% (at 35°C) without condensation, storage environment- 20~45℃, no condensation below 80% relative humidity (at 35℃), data interface RS-232, USB, USB-B, in compliance with standards CIE No.15, GB/T 3978, GB 2893, GB/T 18833 , ISO7724/1, DIN5033 Teil7, JIS Z8722 condition C, ASTM E1164, ASTM-D1003-07, chromaticity value repeatability XLAV chromaticity value: standard deviation within ΔE*ab 0.01, maximum value within ΔE*ab 0.02, reflection Rate resolution 0.01% | |
The above is for reference only, please consult Beichao Technology for more detailed selection.