Temperature analysis, maintenance and repair of constant temperature and Humidity Chamber

Abstract: 为确保恒温恒湿箱的正常运行和延长使用寿命,应定期进行维护和修理。实验前应清除外壳内残留物,并每年至少清扫一次高低压配电室。外壳需每年用肥皂和液体擦洗。冷暖系统软件需在每次实验后检查,如发现异常应及时维修。箱内各部件要定期紧固,并监测冷却系统的毛细管长度。内箱的温度分析需注意箱壁导热系数的不均匀、外壳密封性问题和实验靶材对空气对流的影响,这些因素都会影响温度均匀性。

Maintain and overhaul it on time

1. Before the experiment, everyone should remove the residues in the casing, and the high-low voltage power distribution room should be removed at least once a year. In the case of cleaning, we can use a vacuum cleaner to suck out the dust in the room. Due to the direct contact between the shell and the outside world, the shell of the environmental Test Chamber is easily corroded and polluted. Therefore, the exterior of the housing needs to be cleaned once a year. In case of cleaning, it can be scrubbed with soap and liquid.

2. For the heating and cooling system in the constant temperature and humidity Test Chamber, you must be careful after each experiment. If there is any abnormal phenomenon, it needs to be repaired immediately. Rapid cooling and heating are not possible without preventing the experiment.

3. All parts in the box must not be loose, and must be tightened at intervals. The constant temperature and humidity Test Chamber accurately measures the length of capillaries: the return bronchus is not connected to the refrigeration compressor, and it is opened. Start the refrigeration compressor of the high-low Temperature Test Chamber. After the barometer reading is stable, record the reading at this time to clarify the basis for the new capillary length. Then stop the refrigeration compressor, remove the old capillary from the barometer, and replace it with a new capillary about 2m up and down. Start the refrigeration compressor of the high-low Temperature Test Chamber. The stable reading on the barometer at this point is generally higher than the previously recorded reading. Moderately cut off a section of new capillary.

Temperature analysis of inner box experiment

1. Due to the different thermal conductivity coefficients of the upper, lower, left and right walls of the personal studio, some have wiring holes, inspection holes, and detection holes, which cause partial heat dissipation and heat conduction, making the temperature of the shell uneven, and the radiation of the box wall Asymmetrical heat transfer with extensive flow compromises symmetric temperature.

2. The airtightness of the shell and the door is not tight. If the non-customized sealing tape has seams, door leaks, etc., it will endanger the temperature uniformity of the indoor space during work.

3. If the volume of the experimental target is too large, or the part or method of placing the experimental target in the high-low temperature test environment Test Chamber is not suitable, it will hinder the internal air convection and cause a large error in temperature uniformity. For example, placing the test object on the side of the trachea will seriously damage the wind circulation system, and the uniformity of natural temperature will be greatly damaged.

Temperature Analysis, Maintenance and Repair of Constant Temperature and Humidity Chamber 1