Back
Knowledge

How to do a good job in the regular maintenance and cleaning of the constant temperature and humidity Test Chamber?

Abstract: 文章介绍了恒温恒湿试验箱的定期保养和清洁工作。首先,需每六个月清洁补给水箱和水回收水箱,清洗水位控制浮球组和加湿筒,并清除水垢。水质过滤器应根据水质情况每年更换一次,确保加湿用水的纯净。湿球专用纱布应在变黄或吸水能力下降时更换。冷冻机散热器应每六个月使用强力空气清洁,以增强散热效果。此外,测试区内侧应随时保持干净,以确保设备的正常运作。

1. Cleaning and maintenance of water recycling 

1. The supply Water Tank and the water recovery Water Tank must be cleaned and maintained regularly (once every six months).

2. The water level control float group can be cleaned after removing the connecting screws (once every six months)

3. After removing the six screws around the humidifying cylinder, remove the scale (once every six months).
* Note: Before disassembling, drain the water in the furnace and turn off the main power switch

4. Maintenance of water quality filter. This part is a consumable material and must be replaced regularly (about once a year) depending on the quality of the water. Conversely, if the water quality is poor or the number of times the water returns to the water cycle is high, the frequency of replacement will be higher.
*Note: Always ensure that the quality of the humidification water is pure, and keep replacement parts in stock.

2. Replacement of special gauze for wet bulb

If it is found that the gauze has turned yellow and dirty, and its water absorption capacity is poor, replace it immediately.

3.  Cleaning and maintenance of the radiator of the refrigerator

Powerful AIR can be used to remove dust and increase cooling (every six months).

4. The test area inside the machine should be kept clean at all times

How to do the regular maintenance and cleaning of the constant temperature and humidity Test Chamber?  Picture 1

Products required
Relevant knowledge
Guess you like it