Since each environmental testing equipment is a high-precision instrument, and the volume is usually relatively large, there are countless operating precautions. Let me list with you the matters that should be paid attention to when operating the constant temperature and Humidity Chamber.
1. It is forbidden to disassemble, process, modify or repair the constant temperature and Humidity Chamber without authorization; otherwise, there will be danger of abnormal operation, electric shock or fire.
2. The life of the internal parts of the instrument is limited. In order to continue to use the equipment safely, please perform regular maintenance. When discarding this product, treat it as industrial waste.
3. In order to prevent electric shock or misoperation and misoperation, please do not turn on the power before the installation and wiring are completed.
4. When the instrument is working, please do not open the door of the test temperature and Humidity Chamber. Opening at a high temperature may cause burns to the operator, and opening at a low temperature may cause frostbite to the staff, and the evaporator will freeze, affecting the cooling effect. If unlocking is required, workers need to be protected.
5. The wiring needs to be correct and grounded. Failure to ground may result in electric shock, malfunction accidents, abnormal display, or large measurement errors.
6. If the environmental testing equipment is damaged or deformed when unpacking, please do not use it.
7. Regularly check the terminal screws and fixing frames; please do not use them when they are loose.
8. This product is a non-explosion-proof product and cannot be used in an environment with flammable and explosive gases.
9. In order to avoid machine failure in the program-controlled constant temperature and humidity Test Chamber, please provide a power supply within the rated voltage range.
10. Check whether the power supply is stable before starting the machine.
11. The ventilation holes of the machine body should be kept unobstructed to avoid failure, abnormal operation, shortened life, and fire.
12. During the operation of the instrument, safety should be fully considered before modifying the settings, signal output, start, stop and other procedures; wrong operations may damage the working equipment or cause malfunctions.
13. Wipe the meter with a dry cloth. Do not use alcohol, gasoline or other organic solvents or splash water on the meter when wiping. If the meter is immersed in water, please stop using it immediately; otherwise there is a risk of electric leakage, electric shock or fire.
14. During the operation of the instrument, it is necessary to install the power input terminal cover on the terminal board to prevent electric shock.
15. When installing and setting the cavity, be careful not to let dust, thread ends, iron filings or other things enter; otherwise, malfunctions will occur.
Remember: Remember not to allow non-Testers to operate the device or change its internal parameters. In addition, do not open the door during the test, do not run the machine or non-explosion-proof products with constant temperature and humidity when the equipment sounds the alarm, and do not use the constant temperature and humidity Test Chamber in the environment. with flammable or explosive gases.