Because environmental testing equipment is a high-precision instrument, and the volume is usually relatively large, there will be countless precautions during operation, so here are some suggestions for precautions during operation:
1. It is forbidden to disassemble, process, modify or repair the Incubator without authorization, otherwise there will be danger of abnormal operation, electric shock or fire.
2. The internal parts of the instrument have a certain service life. In order to use the instrument continuously and safely, please perform regular maintenance and maintenance. When disposing of this product, please treat it as industrial waste.
3. In order to prevent electric shock, misoperation and failure, please do not turn on the power before the installation and wiring are completed.
4. Please try not to open the door of the environmental testing equipment during the operation of the instrument. Opening it at high temperatures could result in operator burns. Opening at low temperature may cause frostbite to the staff and may cause the evaporator to freeze, affecting the cooling effect. If it needs to be opened, please do some protection work.
5. The wiring needs to be correct and grounded. Failure to ground may result in electric shock, malfunction, false display or large measurement error.
6. If the machine is damaged or deformed when unpacking, please do not use it.
7. Regularly check the terminal screws and fixing brackets. Don't use them loosely.
8. This product is not explosion-proof. Please do not use the constant temperature and humidity machine in a harsh environment with flammable and explosive gases.
9. In order to avoid machine failure of the constant temperature and humidity Test Chamber, please supply power within the rated voltage range.
10. Check whether the power supply is stable before starting the machine.
11. The ventilation holes of the machine body need to be kept unblocked to prevent failure, abnormal operation, shortened life span and fire.
12. During the operation of the instrument, safety issues should be fully considered before modifying, setting signal output, starting, stopping and other operations. Improper operation can result in damage or malfunction of the working equipment.
13. Wipe the meter with a dry cloth. Do not use alcohol, gasoline or other organic solvents. Do not splash water on the meter. If the meter is immersed in water, please stop using it immediately, otherwise there is a risk of electric leakage, electric shock or fire.
14. During the operation of the instrument, it is necessary to install the power input terminal cover on the terminal board to prevent electric shock.
15. When installing and setting up the machine, be careful not to let dust, thread ends, iron filings or other objects enter, otherwise wrong actions or malfunctions may occur.