5 points to consider in the selection of low temperature and constant Humidity Chamber

Abstract: 本文探讨了低温恒温恒湿箱选型时的五个关键要点。首先,需要选择适合实验需求的温度范围,通常为-40°C至+200°C。再有就是控制方式应选择数字控制或机械控制,数字控制虽然价格较高,但更为准确可靠。第三,容积选择应符合实验规模,避免浪费或不足。第四,选择具有良好温度均匀性的设备,以确保结果的准确性和重复性。最后,安全性是关键,设备应具备过温保护、漏电保护等功能。使用过程中需定期检查和维护设备,保持干燥,避免过载,并确保内部整洁,以延长设备寿命并保证实验准确性。

Constant Temperature Test Chamber is a commonly used experimental equipment, which can be used to simulate various environmental conditions to test the performance of samples under different temperature conditions.

5 key points for selection of low temperature constant temperature and Humidity Chamber with picture 1

Selection points

1. Temperature range: The constant Temperature Test Chamber usually has a temperature range of -40°C to +200°C, and an appropriate temperature range needs to be selected according to the experimental requirements.

2. Control method: There are usually two control methods for constant Temperature Test Chambers: digital control and mechanical control. Digital control is more accurate and reliable, but the price is higher. It is necessary to choose an appropriate control method according to the experimental requirements.

3. Volume: It is necessary to select a suitable volume according to the experimental requirements. Generally, a suitable volume should be selected to avoid waste caused by too small or too large volume or the experiment cannot be carried out.

4. Uniformity: The constant Temperature Test Chamber needs to have good temperature uniformity to ensure the accuracy and repeatability of the test results.

5. Safety: The constant Temperature Test Chamber needs to have good safety performance, such as over-temperature protection, leakage protection and other safety functions.

Precautions

1. Before use, you need to check whether the equipment is in good condition, and confirm whether the sensors, controllers, thermometers, etc. are normal.

2. When using, it is necessary to operate according to the instructions to avoid equipment damage or experiment failure caused by excessive use or improper operation.

3. Avoid overloading during use to avoid damage or danger to the equipment.

4. The interior of the constant Temperature Test Chamber should be placed neatly to avoid improper placement from affecting the experimental results.

5. When adjusting the temperature, it needs to be adjusted gradually to avoid changing too fast and affecting the experimental results.

6. The constant Temperature Test Chamber needs to be kept dry during use to avoid moisture entering the interior of the equipment and affecting the experimental results.

7. It is necessary to regularly check the safety of the constant Temperature Test Chamber, such as checking whether the sealing ring is intact, to ensure the normal operation and safe use of the equipment.

8. After the constant Temperature Test Chamber is out of use for a long time, it is necessary to clean the inside in time and preheat it before re-use.

9. It is necessary to select a suitable test disc or fixture according to the experimental needs, so as to ensure the stability and accuracy of the sample.