China

CNSHP BZY-2 automatic interfacial tension instrument, platinum plate method (platinum ring method)

SE
The BZY-2 automatic surface/interfacial tension instrument uses the platinum plate test method and is easy to operate. The BZY-2 automatic surface/interfacial tension instrument can measure the surface tension change value caused by time changes.
$4294.00/set
PromotionLoading...
Coupon
Model:
Certificate

hengping BZY-2 Liquid surface/interfacial tensIon MeterSPEC

hengping BZY-2 Liquid surface/interfacial tensIon MeterDetails

hengping BZY-2 Liquid surface/interfacial tensIon MeterPacking list

SKU
NB010260
Measuring method
Platinum plate method (platinum ring method)
Surface tension Measurement Range
0~200mN/m
Tare Range
0~200mN/m
Resolution
0.01mN/m
standard error
±0.02mN/m
Repeatability
±0.02mN/m
Display mode
LED display
Measurement time
Low concentration sample 3-5 seconds
Operation mode
Automatic lift
Platform lifting distance
60mm
Interface
RS232C
Data processing software
Software standard
Temperature range
0~110℃
Temperature transducer
PT:100
Net Weight
15
Power
AC220V±10
Dimensions
400*200*400mm
Ordinary thermostatic pool
type
High and low temperature thermostatic pool
Temperature display device
BZY-2
Liquid surface/interfacial tensIon Meter
CNSHP BZY-2 automatic interfacial tension instrument, platinum plate method (platinum ring method) Picture

Introduction

BZY series automatic liquid surface/interfacial tensIon Meter is a laboratory measuring instrument that uses physical methods instead of chemical methods to measure liquid surface/interfacial tension. It can quickly and accurately test the tension values of various liquid-gas surfaces and liquid-liquid interfaces. . Widely used in petroleum, chemical, pharmaceutical, printing, textile, electric power and other industries.

BZY series automatic surface/interface tensIon Meter adopts a professional electromagnetic force closed-loop force value measurement system, single-chip microprocessor control, automatic measurement, easy operation, excellent performance, high-precision test results, high stability, high repeatability, High linearity. The patent number of the surface/interfacial tensiometer is: 200520039453.1. The test method of the surface/interfacial tensiometer: Platinum plate method (or platinum ring) The operation mode of the surface/interfacial tensiometer: automatic lifting and lowering of the sample table, fully automatic measurement

Features

  • Compared with other Surface Tensiometers, BZY series Surface Tensiometers include but not limited to the following advantages:

  • Fully automated measurement to minimize human error;

  • Automatically read the surface tension balance value;

  • One-key reset (any value between 0-400mN), very correct;

  • One-button calibration, with the standard weight attached to the machine, accurate and fast;

  • The platinum plate method is adopted, which fully complies with the requirements of the basic principles of the Wilhelmy platinum plate method, thus providing the possibility to carry out measurements in the following environments:

  • Changes in surface tension values over time due to the presence of surfactants

  • Measurement of high viscosity liquids (automatic reading of balance value)

  • The interfacial tension value between two immiscible liquids, such as oil and water.

  • Sensitive sensor response and high precision make it possible to achieve good repeatability and thus provide comparable data.

  • Simple operation, without any external computer control;

  • The error caused by the machine itself is small, and various errors in the testing process can be controlled more effectively;

  • Sample constant temperature cup, sample temperature detection device and external constant temperature bath can be selected.

Application

The basic function of tensiometer is to test the surface tension of liquid and liquid-liquid interfacial tension. Surfactants are widely used in all walks of life. Surfactants have functions such as emulsification, solubilization, decontamination, and defoaming. The main Applications are introduced as follows:

serial number

Application

use

1

Petrochemical industry

Oil-water interface test; oil product control; determination of operating oil aging degree; flooding fluid quality control

2

printing industry

Ink formulation development, ink wetting and adhesion to printing substrates, pigment dispersion fountain solution quality control, product development and quality control

3

paint, coating industry

The dispersion of pigments, the wetting of the coating film on the substrate and the leveling of the adhesion and application, the stability of the emulsion

4

Pharmaceutical, pesticide industry

Improve the dispersion, emulsification and wetting ability of the drug, optimize the formula, and improve the effect of drug use

5

Cleaning agent industry

Analyze the emulsification, compatibilization and detergency of surfactants, the quality research and concentration selection of surfactants

6

Electroplating industry

The wettability of the plating solution to the substrate, preventing defects such as pinholes and dents, and the quality control of the process drawing

7

Cosmetics industry

Analyze the dispersibility, stability and wettability, compatibilization, thickening, dispersion and emulsification of suspending agent and emulsifier.

8

textile industry

Fuel wettability analysis, adhesion case analysis, textile finishing solution formulation optimization

9

food industry

Surface finishing analysis of raw materials, wettability analysis, surface finishing analysis of packaging layers

10

Water treatment industry

Water purification, sewage treatment, etc.

11

Power Industry

Transformer oil, insulating oil quality control, operating oil aging degree analysis

12

Biological Engineering

Wettability, adsorption, and degradation analysis of polymer materials, and biomaterial engineering

13

research institute

CMC determination of surface materials; research and development of new surfactants;

14

colleges and universities

Development of surfactant Applications, research on surface adsorption theory, development of surface treatment technology, etc.


Display of HENGPINg BZY-2 Automatic Interfacial Tension Meter

FAQ
QOur laboratory mainly does ink formula research, and needs to test the wettability of inks to paper. Do you have a recommended surface tensiometer?
A BZY-2 liquid surface tensiometer uses platinum plate method, which can automatically measure liquid surface tension, simple operation and accurate results. For inks development, it can help you accurately evaluate the wetting and adhesion performance of inks on paper, optimize the formula, and is very suitable for quality control in the printing industry.
QOur chemical plant needs to monitor the interfacial tension changes of two immiscible liquids (such as oil and water), which instrument is suitable?
A The BZY-2 interfacial tension meter can be used for the measurement of liquid-liquid interfacial tension, such as the oil-water interface. The instrument is fully automatic and the Sensor is sensitive, which can accurately track the tension change caused by the presence of surfactants, making it ideal for the Petrochemicals industry for oil quality control and oil displacement analysis.
QIs it the platinum plate method?
A Yes.
Knowledge
Standard