Defelsko PosiTector 6000 NRS3 Film Thickness Gauge 90 degree probe for non-ferrous metal substrates
SE
90 degree eddy Current probe, used for low headroom area thickness measurement, waterproof probe can be underwater measurement; support usb/bluetooth/wifi communication interface; LCD screen can be flipped display and touch operation; with real-time drawing measurement data, batch processing mode, three scanning modes.
Defelsko PosiTector 6000 NRS3 Coating Thickness GaugePacking list
SKU
NB001200
Measurement principle
Eddy Current
Measurement range
0~1500μm
margin of error
±1%
Resolution
0.1μm
probe
NRS3 Probe (Type 90 °)
statistical function
Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation
icon function
Yes.
Power Supply
3 * AAA alkaline battery
Standards
ISO 2178/2360/2808、PrEN ISO 19840、ASTM B499/D1186/D1400/D7091/E376/G12、BS3900-C5、SSPC-PA2等
Calibrated Certificate
Yes.
Language
Chinese, English
Display screen
2.8-Inch color touchscreen
Interface
USB, Bluetooth
supporting software
PosiSoft Software Suite
Machine Weight
137G (without battery)
Machine size
127*66*25.4mm
Data storage
250000 Measured values, 1000 groups
Test environment
Non-ferrous metal substrate nonconductive coating environment
Defelsko calibrated standard
STDA1
screen image saving
One hundred.
Protection level
IP65
Measurement speed
More than 180 readings per minute
PosiTector 6000 NRS3
Coating Thickness Gauge
90 degree eddy Current probe, used for low headroom area thickness measurement, waterproof probe can be underwater measurement; support usb/bluetooth/wifi communication interface; LCD screen can be flipped display and touch operation; with real-time drawing measurement data, batch processing mode, three scanning modes.
Introduction
The Defelsko PosiTector 6000 NRS3 Paint Film Thickness Gauge is an eddy current coating Thickness Gauge that measures a 90° probe with good wear resistance, suitable for measuring non-conductive coatings on non-ferrous coatings such as aluminum and copper, and the thickness of the measured coating is in the range of 0~1500 micronsThe color LCD display clearly displays the measured valuesto support the screenshot function.PosiTector 6000 NRS3 Coating Thickness GaugeIt is suitable for testing coating thickness in coatings, inks, plastics, leather, building materials, chemical and other fields.
Packing list:host x1, split probe x1, standard test piece (set) x1, rubber protective cover with waist clip x1, No. 7 battery x3, certificate x1, manual x1, nylon bag x1.
[Note]Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
QI want to measure the thickness of paints on Aluminum Panels, which thickness gauge should I choose?
A
Recommended Defelsko PosiTector 6000 NRS3, it uses the eddy current principle, specially used for the measurement of non-conductive coatings on non-ferrous metals such as aluminum and copper. Measurement range 0-1500 microns, high accuracy, Probe wear-resistant and durable, suitable for your needs.
QWhere is this thickness gauge commonly used in industrial inspection?
A
It is widely used in coatings, inks, plastics, building materials and other industries, such as testing Aluminum profile surface coatings, copper product insulation layers, etc., because it can accurately measure the nonconductive Coating thickness on non-ferrous metals, in line with a number of international standards.
QDo the Defelsko 6000 series thickness gauges come standard with software?
A
This does not have a physical software CD, but PosiSoft software can be downloaded for free on the manufacturer's official website for downloading and viewing data reports.
QWhy can't the Defelsko Coating thickness gauge be charged?
A
Hello, there are two solutions: 1. It is equipped with 3 ordinary AA batteries, please open it and replace it; 2. It can also be connected to a computer for direct use, but it cannot be charged (powered by a USB cable).
QWhat is the difference between NRS1 and NRS3 film thickness gauges?
A
Hello, one of NRS1 and NRS3 is a standard type, and the other is an advanced type. The thickness measurement range is the same, but NRS3 will be more powerful in function. For details, please see the introduction of the corresponding product.
QDo you have the Coating thickness gauge involved in ASTME376?
A
The PosiTector 6000 NRS3 Coating thickness gauge will do