China

YIHENG BPH-9162 precision Thermostatic Incubator foster Thermostatic Chamber

SE
Temperature range RT + 5~ 80 ℃, Temperature resolution 0.1 ℃, Temperature fluctuation +/- 0.2 ℃, Temperature uniformity +/- 1.5 ℃, Ambient Operating Temperature + 5~ 35 ℃, liner size 500 * 380 * 750mm
$1014.00/set
PromotionLoading...
Coupon
Model:

YiHeng BPH-9162 Precision Thermostatic IncubatorSPEC

YiHeng BPH-9162 Precision Thermostatic IncubatorDetails

YiHeng BPH-9162 Precision Thermostatic IncubatorPacking list

SKU
NB012775
Power
AC 220V 50Hz
Temperature range
RT+5~80℃
Temperature Resolution
0.1℃
Temperature Fluctuation
±0.2℃
Temperature Uniformity
±1.5℃
Ambient Temperature
+5~35℃
Liner size
500*380*750mm
Dimensions
655*715*980mm
Shelf (std.)
2pcs
Shelf (max.)
4pcs
Input Power
500W
BPH-9162
Precision Thermostatic Incubator
Temperature range RT + 5~ 80 ℃, Temperature resolution 0.1 ℃, Temperature fluctuation +/- 0.2 ℃, Temperature uniformity +/- 1.5 ℃, Ambient Operating Temperature + 5~ 35 ℃, liner size 500 * 380 * 750mm
YIHENG BPH-9162 precision Thermostatic Incubator foster Thermostatic Chamber Picture

Features

◆Humanized design

● Large-screen LCD display, multiple groups of data displayed on one screen, menu-style operation interface, easy to understand, easy to observe and operate.

●Mirror stainless steel liner is adopted, the four corners are semi-circular transition, and the shelf bracket can be freely loaded and unloaded, which is convenient for the cleaning work of the studio.

● Unique air duct circulation system ensures uniform temperature in the working room. The right side of the cabinet is equipped with a test hole with a diameter of 25mm, which can be arbitrarily wired according to the needs of the place where it is placed.


◆Quality Assurance

● Fuzzy PID controller, accurate temperature control with little fluctuation, with timing function, the maximum time setting value is 99 hours and 59 minutes.

● Multi-segment programmable control can simplify the complex test process and truly realize automatic control and operation. (standard configuration)


◆Circulation fan speed automatic control

● The speed of the circulating fan can be automatically controlled. When the temperature in the box is at a constant temperature, the speed will decrease, and the circulating wind speed will be adjusted to the wind speed suitable for cell growth, so as to avoid volatilization of samples due to excessive air volume during the test.


◆Self-diagnosis function

● When the Incubator breaks down, the LCD will display the failure information, and the fault point can be seen at a glance.

◆Convenient data processing (optional)

● It can be connected to a printer or 485 communication interface, and has a USB data transfer interface (U disk) to record temperature and time with a computer and a printer, providing a strong guarantee for data storage and playback during the test process.


◆Security function

● Independent temperature limit alarm system, and sound and light alarm to remind the operator to ensure safe operation without accidents. (optional)

● High or low temperature and over-temperature alarm.


◆Multi-segment programmable controller

● Multi-segment LCD programmable controller, one-screen display of various parameters, and menu-style operation interface can simplify the complicated test process and truly realize automatic control and operation.

● Parameters such as multi-stage temperature, circulating wind speed, time and heating rate can be set and programmed at the same time. It can control the gradient of temperature rise, slowly rise from the initial temperature in the box, and can also preset functions such as automatic startup, standby and shutdown.

● 7 groups of 63 steps can be preset, each group has 9 steps, and each group can set the time from 0 to 5999 minutes.


◆ Ultraviolet sterilization system (optional)

The inside of the box can be disinfected regularly, which can effectively kill the floating bacteria in the circulating air in the box, thereby effectively preventing pollution during cell culture.


Options:

  • Embedded printer

  • Independent temperature limit controller

  • RS485 interface and communication software

  • UV sterilization system.

  • U disk data storage

Note: Choose one of U disk, RS485/232, and printer


Model Selection

modelBPH-9042BPH-9082BPH-9162BPH-9272BPH-9402
VoltageAC220V 50HZ
Temperature control rangeRT+5~80℃
Temperature resolution/fluctuation0.1℃/±0.2℃
temperature uniformity±1.5°C (test point is 37°C)
Working temperature+5~35℃
input power250W250W500W600W1200W
Inner tank size (mm) W×D×H350×300×400400×320×550500×380×750600×450×9001000×510×800
Dimensions (mm) W×D×H505×635×600550×660×750655×715×980755×785×11301140×850×1080
Carrier (standard)2 pieces
FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.