Ceramic Glossmeter JFL-B45 (Ceramic, Plastic film common type) JFL

SE
JFL-B45 ceramic Glossmeter is a common type of 45-degree single-angle Gloss Meter. JFL-B45 ceramic Glossmeter is mainly used for the measurement of surface Glossiness of Plastic films, ceramics, enamels, lacquerware, etc.
$400.00/set
PromotionLoading...
Coupon
Certificate

JFL JFL-B45 (Ceramic, Plastic film common type) GlossmeterSPEC

JFL JFL-B45 (Ceramic, Plastic film common type) GlossmeterDetails

JFL JFL-B45 (Ceramic, Plastic film common type) GlossmeterPacking list

SKU
NB001300
Geometry
45°
Measurement range
0~199.9GU
Measuring Areas
10*14mm
Error of indication
±1.2GU
Division Value
0.1GU
Standards
ASTM-C346、ASTM-D2457、GB8807、GB/T3295
Operating language
Chinese
Dimensions
114*35*65mm
Weight
300g
Power
1 AA battery
Stability
±0.4GU
Measurement port size
14*20mm
Working Voltage
1.5V
Application
Plastic film, Pottery and porcelain, Enamel, Lacquerware
Measurement port shape
ellipse
JFL-B45 (Ceramic, Plastic film common type)
Glossmeter
Ceramic Glossmeter JFL-B45 (Ceramic, Plastic film common type) JFL Picture

Introduction

Jinfulan JFL-B45 ceramic gloss meter is a ceramic gloss meter with a projection angle of 45 degrees. The display range is 0.0-199.9Gs. The measurement window of the gloss meter is an oval measuring port of 1.5x3mm. JFL-B45 ceramic gloss meter is a gloss meter produced according to the national standard JJG696. The measurement is very stable. It is widely used in the fields of ceramics and plastic films.

Applications

The Applications of JFL-B45 ceramic gloss meter are: plastic film, ceramics, enamel, lacquerware.

operation method

1. Press the switch of the JFL-B45 ceramic gloss meter, place the JFL-B45 single-angle gloss meter on the black glass standard plate, and turn the adjustment knob to make the displayed value the same as the nominal value of the standard plate.

2. Put the JFL-B45 ceramic gloss meter on the white ceramic standard plate, and the error between the displayed value and the nominal value of the white ceramic standard plate should not be greater than ±1.2 gloss units, otherwise, you should consider whether the standard plate is dirty or not.

3. When the gear error is out of tolerance, it needs to be recalibrated.

4. After calibration, the sample can be measured. When the measured value exceeds 199.9 gloss units, an overflow "1" will be displayed.