Back

TIMES TT260FN Coated platings Thickness Gauge Specifications

Search
TIMES TT260FN platings Thickness Gauge with probes F1 and N1

Brand:TIMES

Model:TT260FN

Name:Coated platings Thickness Gauge

DetailsContact
Specifications
Measurement principle Magnetic Induction + eddy Current
Measurement range 0~1250μm
margin of error One point calibrate (μm ) : +/- [ 3% H + 1 ] 、 +/- [ 3% H + 1.5]; two point calibrate (μm ): +/- [( 1~ 3) % H + 1 ] 、 +/- [( 1~ 3) % H + 1.5]
resolution 0.1μm
Minimum measurement surface Φ7mm、Φ5mm
Minimum radius of curvature Convex 1.5mm, 3mm
thinnest substrate 0.5mm、0.3mm
probe F1 or N1
statistical function Single measurement, continuous measurement
statistical function Measurement times, MAX Maximum, MIN Minimum, Average, Standard deviation
Data storage 495 Measured values
Voltage 3.0V
Operating temperature 0~40℃
Relative Humidity 20~90%RH
Operating Mode Direct mode (DIRECT) and group mode (Appl)
Weight 530g
Dimension 270*86*47mm
shutdown mode Manual/Automatic
Packing list
host X1, standard piece set X1, base X1, (F1 and N1) probe X1, charger X1, manual X1, certificate X1, warranty card X1
After-sales instructions

Warranty days: 1068 days

[Note] For after-sales services outside the Chinese mainland, if the instrument requires repair, the shipping and possible associated taxes shall be borne by the sender. Generation address of the manual: http://en.nbchao.com/p/13328/Specification.html , which is only used by users who purchase commodities from the NBCHAO.