Coating Thickness Gauge AMITTARI AC-110BS Coating Thickness Gauge

SE
Magnetic Induction and eddy Current dual function, can test magnetic and nonmagnetic substrate, thickness range 0~1250μm, error +/- 3%, can store 99 sets of data, in line with ISO2178, ISO2360, GB4956, GB4957 standards.
$506.00/set
PromotionLoading...
Coupon
Model:
Certificate

AMITTARI AC-110BS Coating Thickness GaugeSPEC

AMITTARI AC-110BS Coating Thickness GaugeDetails

AMITTARI AC-110BS Coating Thickness GaugePacking list

SKU
NB001464
Measurement principle
Magnetic induction + eddy current
Measuring range
0 ~ 1250µm
margin of error
±3%
resolution
0.1µm
Minimum headroom
90mm
Minimum radius of curvature
F: convex 1.5mm/concave 25mm; N: convex 3mm/concave 50mm
thinnest matrix
0.3mm
probe
F and NF split probes
icon function
without
Power
2 * AAA 1.5V battery
Standards
ISO2178、ISO2360、GB4956、GB4957
Calibrated Certificate
without
Language
Chinese
Display screen
4-Bit digital backlight LCD
Data Interface
RS-232、USB、Bluetooth
supporting software
Yes (optional)
Total Weight
90G (without battery)
Complete-built unit size
130*63*24mm
data storage
99 sets of data
Minimum measurement surface
F6mm
Statistical function
Single measurement, continuous measurement
Operating Temperature
0~50℃
Optional accessories
USB data cable output, Bluetooth Bluetooth Data output
Relative Humidity
<80% RH
AC-110BS
Coating Thickness Gauge
Magnetic Induction and eddy Current dual function, can test magnetic and nonmagnetic substrate, thickness range 0~1250μm, error +/- 3%, can store 99 sets of data, in line with ISO2178, ISO2360, GB4956, GB4957 standards.
Coating Thickness Gauge AMITTARI AC-110BS Coating Thickness Gauge Picture

Coating Thickness Gauge Selector

product description

An Miao AC-110BS Statistical Coating Thickness Gauge (split type) adopts the principle of magnetic induction and eddy current, which can measure all substrates, whether ferrous or non-ferrous; it can store 99 sets of new measurement data values; and With USB data connection and Bluetooth transmission function; the split statistical coating Thickness Gauge provides a variety of probes, making the measurement more mobile.

AC-110BS Statistical Coating Thickness Gauge measurement method complies with international standards ISO2178, ISO2360 and national standards GB4956, GB4957. It adopts computer technology, non-destructive testing technology and other professional technologies to accurately measure the thickness of the measured object without damaging it.

Functional structure

An Miao AC-110BS Statistical Coating Thickness Gauge Function Structure Diagram

3-1 RS-232C interface; 3-2 Display; 3-3 Add a key; 3-4 Battery cover; 3-5 Delete key; 3-6 Sensor; 3-7 Power key; 3-8 Read key; 3 -9 wrist rope buckle; 3-10 minus one button

Features and advantages

* Wide measuring range and high resolution.

* Automatic memory calibration value, easy to use.

* Small size and light weight.

* Digital backlight display, no parallax.

* The AMITTARI AC-110BS Statistical Coating Thickness Gauge is equipped with an automatic shutdown function to save power.

* The F-type probe can directly measure the thickness of the non-magnetic coating layer (such as: paint, plastic, enamel, copper, aluminum, zinc, chromium, etc.) on the surface of magnetic-conductive materials (such as iron and nickel). It can be applied to the thickness measurement of electroplating layer, paint layer, enamel layer, aluminum tile, copper tile, babbitt tile, phosphating layer, paper, and also can be used for thickness measurement of hull paint and attachments of underwater structural parts.

* Nf type probe can measure the thickness of the insulating covering layer on the non-magnetic metal substrate, such as paint, plastic, rubber coating on the surface of aluminum, copper, zinc, non-magnetic stainless steel, etc., and can also measure the thickness of aluminum or aluminum alloy materials Anodized layer thickness.

* The spring guide sleeve probe with wear-resistant hard metal probe can not only measure on hard or rough surfaces, but also ensure that the probe has constant pressing force and stable sampling value.

* It can store 99 sets of data; realize the statistical function of AC-110BS statistical coating Thickness Gauge by measuring the average value, maximum value and minimum value .

* With the optional RS232C software and cable, it can communicate with PC computer to realize the functions of data collection, processing, analysis and printing.

Pictures

Appearance of AMITTARI AC-110BS Statistical Coating Thickness Gauge

An Miao AC-110BS Statistical Coating Thickness Gauge Operation Panel Diagram

An Miao AC-110BS Statistical Coating Thickness Gauge Interface Details

Side View of AMITTARI AC-110BS Statistical Coating Thickness Gauge

An Miao AC-110BS Statistical Coating Thickness Gauge Probe Details


FAQ
QWhat are the benefits of AC-110BS with and without cable?
A Split AC-110BS is more used for small workpieces. The probe is small, the measurement is very flexible, and the operator's technique is also certain.
QIs there any difference in measurement accuracy between statistical and different types?
A There is no difference, the main difference is the host power and data processing, the probe is the same.
QDoes the AMITTARI statistical Coating thickness gauge meet the ASTMB499 standard?
A The AC-110BS statistical Coating thickness gauge can refer to
Standard