Back

Bante Bante900P-CN Portable Multi-Parameter Water Quality Meter Specifications

Search
Bante900P-CN Portable multiparameter Water Quality Meter

Brand:Bante

Model:Bante900P-CN

Name:Portable Multi-Parameter Water Quality Meter

DetailsContact
Specifications
PH range -2.000~20.000pH
Measurement Accuracy of pH ±0.002pH
pH resolution 0.1, 0.01, 0.001 pH, optional
pH calibrating point 1 to 5 point
pH calibrating solution USA, NIST, DIN, Custom
pH temperature compensation range 0~100℃
pH temperature compensation Manual/Automatic
ORP Measurement range ±1999.9mV
mV Measurement Accuracy ±0.2mV
mV resolution 0.1/1 mV, optional
mV calibrated point 1 point (only for R.mV mode)
mV calibrated range ±200mV
Measurement range 0.001~ 19999ppm, mg/L, mol/L (please refer to the ionic electrode description for the actual range)
Measurement Accuracy +/- 0.5% F. S (diion ), +/- 1% F. S (diion)
Ion resolution 0.001, 0.01, 0.1, 1
Ion calibrated point 2 to 5 point
Ion calibrating fluid 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
Ion temperature compensation range 0~100℃, 32~212°F
Ion temperature compensation Manual or automatic
Conductivity range 0~20mS/cm (max. 200mS/cm)
Measurement Accuracy of conductivity ±0.5%FS
EC resolution 0.001, 0.01, 0.1, 1
Conductivity calibrated point 1 to 5 point
Conductivity calibrating fluid 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
EC Temperature Compensation Range 0~100℃, 32~212°F
EC Temperature Compensation Mode Manual or automatic
EC Temperature Compensation Coefficient 0.0~10.0%/℃
EC Temperature Compensation Mode mode Linear or pure water
Conductivity Detector cell constant K = 0.1, 1, 10, custom
Standardized temperature 20 ℃, 25 ℃, optional
TDS range 0~10.00, 100.0, 1000ppm, 10.00, 100ppt (maximum 200ppt)
TDS Measurement Accuracy ±1%FS
TDS conversion factor 0.1~ 1.0 (default 0.5)
Salinity range 0~10ppt (max 200ppt)
Measurement Accuracy of salinity ±1%FS
Measurement mode of salinity Utility salinity (psu) or seawater salinity (ppt)
Resistivity range 0~10MΩ (up to 20MΩ)
Measurement Accuracy of resistivity ±1%FS
Resistivity resolution 0.01, 0.1, 1
DO range 0.00~20.00mg/L
DO Measurement Accuracy ±0.2mg/L
DOS resolution 0.1, 0.01 mg/L, optional
DO temperature compensation range 0~50℃
DO temperature compensation automatic
Pressure compensation range 60.0~112.5kPa, 450~850mmHg
Salinity compensation range 0~50g/L
DO% Measurement range 0.0~200.0%
DO% Measurement Accuracy ±2.0%
DO% resolution 0.1, 1%, optional
Measurement range 0~105℃, 32~221℉
Measurement Accuracy ±0.5℃
Temperature Resolution 0.1℃
Temperature calibrating point 1 point
Temperature unit ℃, ° F, optional
Data stability condition Fast or high-precision
Calibrated reminder 1 to 31 days or closed
shutdown mode Manual or automatic (10, 20, 30 minutes after no button operation)
Data storage 500 sets
Communication interface USB
Connector BNC, 6-pin MINI Connector
Power Supply 3 AA batteries
Battery life Approximately 150 hours (when the LCD backlight is turned off)
Dimension 170*85*30mm
instrument Weight 300g
Optional Accessories P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode
Optional Accessories P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode, 501 type ORP electrode, 502 type ORP electrode
Optional Accessories Cd-US cadmium ion selective electrode, Cn-US cyanide ion selective electrode, NH4-US ammonium ion selective electrode, Na-US sodium ion selective electrode, CL-US chloride ion selective electrode, F-US fluorine ion selective electrode, Ca-US calcium ion selective electrode, NO3-US nitrate ion electrode, Br-US bromine ion selective electrode,
Optional Accessories NH3-US Ammonia Gas sensing electrode, S-US sulfur ion selective electrode, K-US potassium ion selective electrode, Ag-US silver ion selective electrode, Cu-US copper ion selective electrode, I-US iodine ion selective electrode, Pb-US lead ion selective electrode,
Optional Accessories Conductivity Detector electrode of CON-0.1 type, Conductivity Detector electrode of CON-1 type, Conductivity Detector electrode of CON-10 type, DO100 type dissolved Oxygen electrode
Optional Accessories TP-10K temperature probe, dissolved Oxygen electrode membrane cap, dissolved Oxygen electrode filling solution, Conductivity Detector standard solution, ion standard solution, ion strength adjuster, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard)
Packaging Dimensions 430*310*100mm
Encasement Weight 2kg
Packing list
Host X1, plastic carrying case X1, E201-BNC type pH electrode X1, Con-1 type Conductivity detector electrode X1, DO100 type dissolved Oxygen electrode (made in the United States) X1, TP-10K type temperature probe X1, pH standard buffer reagent (pH4.01/7.00/10.01) X1, Conductivity detector standard solution (84uS/cm, 1413uS/cm, 12.88mS/cm) X1, dissolved Oxygen electrode filling solution X1, dissolved Oxygen electrode film cap X1, AA type battery X1, manual X1, certificate X1, warranty card X1
After-sales instructions

Warranty days: 365 days

1. For product quality problems caused by non-human products of instruments and equipment, the manufacturer will provide free warranty services during the warranty period;

2. There is no warranty period for fragile and consumable parts, and if you find product quality problems after receiving the goods, please apply for return and exchange within 7 days, and you will not wait for the overdue ones;


[Note] For after-sales services outside the Chinese mainland, if the instrument requires repair, the shipping and possible associated taxes shall be borne by the sender. Generation address of the manual: http://en.nbchao.com/p/14739/Specification.html , which is only used by users who purchase commodities from the NBCHAO.