China

SE
$876.00/set
PromotionLoading...
Coupon
Model:
Certificate

Bante SPEC

Bante Details

Bante Packing list

SKU
NB014740
PH range
-2.000~20.000pH
Measurement Accuracy of pH
±0.002pH
pH resolution
0.1, 0.01, 0.001 pH, optional
pH calibrating point
1 to 5 point
pH calibrating solution
USA, NIST, DIN, Custom
pH temperature compensation range
0~100℃, 32~212°F
pH temperature compensation
Manual/Automatic
ORP Measurement range
±1999.9mV
Measurement Accuracy of mV
±0.2mV
mV resolution
0.1, 1mV, optional
mV calibrated point
1 point (only for R.mV mode)
mV calibrated range
±200mV
Measurement range
0.001~ 19999ppm, mg/L, mol/L (please refer to the ionic electrode description for the actual range)
Measurement Accuracy
+/- 0.5% F. S (diion ), +/- 1% F. S (diion)
Ion resolution
0.001, 0.01, 0.1, 1
Ion calibrated point
2 to 5 point
Ion calibrating fluid
0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
Ion temperature compensation range
0~100℃, 32~212°F
Ion temperature compensation
Manual or automatic
Conductivity range
0~20mS/cm (最大 200mS/cm)
Measurement Accuracy of conductivity
±0.5%FS
EC resolution
0.001, 0.01, 0.1, 1
Conductivity calibrated point
1 to 5 point
Conductivity calibrating fluid
10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
EC Temperature Compensation Range
0~100℃, 32~212°F
EC Temperature Compensation Mode
Manual or automatic
EC Temperature Compensation Coefficient
0.0~10.0%/℃
EC Temperature Compensation Mode mode
Linear or pure water
Conductivity Detector pool constant
K = 0.1, 1, 10, custom
Standardized temperature
20 ℃, 25 ℃, optional
TDS range
0~10ppt (maximum 200ppt)
TDS Measurement Accuracy
±1%FS
TDS conversion factor
0.1~ 1.0 (default 0.5)
Salinity range
0~10ppt (maximum 80ppt)
Measurement Accuracy of salinity
±1%FS
Measurement mode of salinity
Utility salinity (psu) or seawater salinity (ppt)
Resistivity range
0 ~ 10MΩ (? 20MΩ)
Measurement Accuracy of resistivity
±1%FS
Resistivity resolution
0.01, 0.1, 1
DO range
0.00~20.00mg/L
DO Measurement Accuracy
±0.2mg/L
DOS resolution
0.1, 0.01 mg/L, optional
DO temperature compensation range
0~50℃
DO temperature compensation
automatic
Pressure compensation range
60.0~112.5kPa, 450~850mmHg
Salinity compensation range
0~50g/L
DO% Measurement range
0.0~200.0%
DO% Measurement Accuracy
±2.0%
DO% resolution
0.1, 1%, optional
Measurement range
0~105℃, 32~221℉
Measurement Accuracy
±0.5℃
Temperature Resolution
0.1℃
Temperature calibrating point
1 point
Temperature unit
℃, ° F, optional
Data stability condition
Fast or high-precision
Calibrated reminder
1 to 31 days or closed
shutdown mode
Manual or automatic (10, 20, 30 minutes after no button operation)
Data storage
500 sets
Communication interface
USB
Connector
BNC, 6-pin MINI Connector
Power Supply
3 AA batteries
Battery life
About 150 hours (when the LCD backlight is turned off)
Dimensions
170*85*30mm
Instrument Weight
300g
Optional Accessories
P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode
Optional Accessories
P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode, 501 type ORP electrode, 502 type ORP electrode
Optional Accessories
Cd-US cadmium ion selective electrode, Cn-US cyanide ion selective electrode, NH4-US ammonium ion selective electrode, Na-US sodium ion selective electrode, CL-US chloride ion selective electrode, F-US fluorine ion selective electrode, Ca-US calcium ion selective electrode, NO3-US nitrate ion electrode, Br-US bromine ion selective electrode,
Optional Accessories
NH3-US Ammonia Gas sensing electrode, S-US sulfur ion selective electrode, K-US potassium ion selective electrode, Ag-US silver ion selective electrode, Cu-US copper ion selective electrode, I-US iodine ion selective electrode, Pb-US lead ion selective electrode,
Optional Accessories
Conductivity Detector electrode of CON-0.1 type, Conductivity Detector electrode of CON-1 type, Conductivity Detector electrode of CON-10 type, DO100 type dissolved Oxygen electrode
Optional Accessories
TP-10K temperature probe, dissolved Oxygen electrode membrane cap, dissolved Oxygen electrode filling solution, Conductivity Detector standard solution, ion standard solution, ion strength adjuster, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard)
Packaging Dimensions
430*310*100mm
Encasement Weight
2kg
 Picture

Bante900P Portable pH/Conductivity/Dissolved Oxygen Meter

Multi-parameter portable pH meter with 8 measurement functions, the instrument is suitable for outdoor measurement of pH, redox potential, ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation of liquids.

Functional characteristics of pH mode

• Multi-parameter Water Quality Analyzer with large backlit LCD screen.

• 1 to 5 point push-button calibration for automatic recognition of pH standard buffers.

• Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.

• Automatic electrode slope display to prompt the user whether to change the pH electrode.

Functional features of ORP mode

• 1-point offset calibration that allows adjustment of the display value to a known standard.

• Relative and absolute mV modes provide accurate ORP readings.

Portable pH meter

Ionic mode features

• 2 to 5 pushbutton calibration, including 8 concentration calibration points.

• Automatic identification of ion-selective electrodes without the need to specify the ion type.

• Direct reading of ion concentration values to avoid tedious conversions and calculations.

• Concentration units (ppm, mg/L, mol/L) are available to meet a variety of ion measurement needs.

Conductivity/TDS/Salinity/Resistivity mode features

• 1 to 5 point key calibration for automatic identification of conductivity standards.

• Selectable cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation,

  Seawater and practical salinity measurement mode.

Portable pH meter


Functional characteristics of dissolved oxygen mode

• 1 or 2 button calibration, using air saturated water or zero oxygen solution.

• Salinity and atmospheric pressure compensation to improve the measurement accuracy of the instrument.

Generic features

• Automatic temperature compensation for accurate measurements over the full scale.

• Automatic calibration reminder to remind the user to calibrate the meter regularly.

• Automatic endpoint locking, stable measured values are retained for easy browsing and recording.

• Automatic electrode diagnostics with zero offset, electrode slope, range and conductivity K values.

• The system menu can customize 15 functional parameters such as the number of calibration points, stability standard, data lock mode, automatic shutdown, etc.

• One-key Reset automatically restores the meter to factory default settings.

• Extended memory for up to 500 sets of measurement data.

• Built-in clock automatically marks the date and time of stored data to comply with GLP specifications.

• USB communication interface to send stored data to a personal computer.

• Multi-mode power supply scheme (battery, power adapter, USB port of the computer) to ensure smooth operation of the instrument.

FAQ
QHow often are water measuring instruments calibrated?
A The first use or replacement of new electrodes must be calibrated. In addition, it should be calibrated regularly.
QHow to calibrate STIP-scan temperature?
A Specific operations: 1. Ensure that the temperature probe is connected to the meter; 2. Press and hold the ℃ key for 3 seconds, the meter enters the temperature calibrate mode, and the screen displays the current temperature value; 3. Press up or down to set the temperature value; 4. Press the enter key to confirm, the calibrate is complete.
QThe screen displays --- what is the reason?
A There are two possible reasons: 1. The electrode Sensors are too drying, which can be solved by immersing in tap water for 10 minutes; 2. Measured value Excessive range: Check whether the Sensors are clean and not contaminated.
Standard