China

Bante920-CN Laboratory pH Meter

SE
Standard laboratory pH Meter, 5-point button calibrated, automatic temperature compensation, 9 functional parameters can be customized in the setting menu, the instrument is suitable for the measurement of pH and Oxidation-reduction potential of samples, Measurement accuracy: 0.002pH.
$410.00/set
PromotionLoading...
Coupon
Model:
Certificate

Bante Bante920-CN Laboratory pH MeterSPEC

Bante Bante920-CN Laboratory pH MeterDetails

Bante Bante920-CN Laboratory pH MeterPacking list

SKU
NB014754
PH range
-2.000~20.000pH
PH measurement Accuracy
±0.002pH
resolution
0.1/0.01/0.001pH/optional
Temperature Measurement range
0~100℃/32~212℉
Power
DC5V power adapter
Dimensions
210*188*60mm
Weight
1.5kg
PH calibrated
1 to 5 point
Calibrating fluid
USA, NIST, DIN, custom
mV range
-1999.9~1999.9mV
mV measurement Accuracy
±0.2mV
mV resolution
0.1|1mV
ORP calibrated point
1 point (only for R.mV mode)
mV calibrated range
±200mV
Temperature Measurement range
0~105℃/32~221℉
Temperature measurement Accuracy
±0.5℃
temperature resolution
0.1℃
Temperature calibrating point
1 point
Temperature unit
℃, ° F, optional
data lock
Manual or automatic end point locking
Data stability condition
Fast or high precision
Calibrated reminder
1 to 31 days or closed
shutdown mode
Manual or automatic (10, 20, 30 minutes after no button operation)
One-click reset function
contain
data storage
500 groups
Communication interface
USB
Connector
BNC
Display
Customized LCD (130 * 110mm)
Optional accessories
P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode, P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode
Optional accessories
Type 501 ORP electrode, Type 502 ORP electrode, TP-10K temperature probe, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard),
Packaging Dimensions
300*240*170mm
Encasement Weight
1.7kg
Temperature compensation method
Automatic/Manual
Bante920-CN
Laboratory pH Meter
Standard laboratory pH Meter, 5-point button calibrated, automatic temperature compensation, 9 functional parameters can be customized in the setting menu, the instrument is suitable for the measurement of pH and Oxidation-reduction potential of samples, Measurement accuracy: 0.002pH.
Bante920-CN Laboratory pH Meter Picture

Bante920 Precision LABOratory pH Meter

Precision laboratory pH meter, 5-point key calibration, automatic information prompt, built-in system menu can customize 9 functional parameters, the meter is suitable for measuring pH and redox potential of samples, measurement accuracy: 0.002pH.

pH Mode Features

• Precision laboratory pH meter with large backlit LCD display.

• 1 to 5 point key calibration, automatic identification of pH standard buffer.

• Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.

• Automatic electrode slope display, prompting the user whether to replace the pH electrode.

• Automatic temperature compensation to ensure accurate measurement over the full range.

• Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.

Precision pH Meter


Functional characteristics of ORP mode

• 1-point offset calibration, allowing adjustment of displayed values to known standards.

• Relative and absolute mV modes provide accurate ORP readings.

common features

• Automatic end point locking, retaining stable measurement values for easy viewing and recording.

• Automatic electrode diagnosis, you can check the zero offset and electrode slope.

• The system menu can customize 9 functional parameters such as the number of calibration points, stability standard, display resolution, data lock mode, and automatic shutdown mode.

• One key reset (Reset) automatically restores the instrument to the factory default settings.

• Expanded memory can store up to 500 sets of measurement data.

• The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.

• USB communication interface to send stored data to PC.