China

Bante931-Ca laboratory Ion Meter calcium Ion Meter

SE
Precision laboratory calcium Ion Meter, 5-point button calibrated, automatic end point locking, the instrument is suitable for measurement of calcium Ion concentration of samples, Measurement accuracy: 1% F.S.
$671.00/set
PromotionLoading...
Coupon
Model:
Certificate

Bante Bante931-Ca Laboratory Ion MeterSPEC

Bante Bante931-Ca Laboratory Ion MeterDetails

Bante Bante931-Ca Laboratory Ion MeterPacking list

SKU
NB014783
Measurement range
5×10-7~1M, 0.02~4000ppm
Measurement Accuracy
±1% F.S
Display resolution
0.001, 0.01, 0.1, 1
Ion calibrated point
2 to 5 point
Measurement mode
0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
Measurement range mV
-1999.9~1999.9mV
Measurement Accuracy of mV
±0.2mV
mV Display resolution
0.1mV
Measurement range
0~105℃, 32~221℉
Measurement Accuracy
±0.5℃
Display resolution
0.1℃
Temperature calibrating point
1 point
Temperature unit
℃/℉
data lock
Manual or automatic end point locking
Data stability condition
Fast or high-precision
Calibrated reminder
1 to 31 days or closed
shutdown mode
Manual or automatic (10, 20, 30 minutes after no button operation)
One-click reset function
contain
data storage
500 sets
Interface
USB
Connector
BNC
Display
Customized LCD screen (130 × 110mm)
Power supply type
DC5V power adapter
Dimensions
210*188*60*mm
Instrument Weight
1.5kg
Optional Accessories
Ca-US calcium ion selective electrode, ion standard solution, ion strength regulator, TP-10K temperature probe
Packaging Dimensions
300*240*170mm
Encasement Weight
1.7kg
Bante931-Ca
Laboratory Ion Meter
Precision laboratory calcium Ion Meter, 5-point button calibrated, automatic end point locking, the instrument is suitable for measurement of calcium Ion concentration of samples, Measurement accuracy: 1% F.S.
Bante931-Ca laboratory Ion Meter calcium Ion Meter Picture

Bante931-Ca Calcium Ion Concentration Meter

Precision calcium ion concentratIon Meter, 5-point button calibration, automatic endpoint locking, the instrument is suitable for laboratory measurement of calcium ion concentration value of liquid samples, measurement accuracy: 1% F.S.

Features

• Precision calcium ion concentratIon Meter with large backlit LCD screen.

• 2 to 5 push-button calibration, optional 8 ion concentration calibration points.

• Direct reading of ion concentration values to avoid tedious conversions and calculations.

• Concentration units (ppm, mg/L, mol/L) are available to meet a variety of ion measurement needs.

• Automatic temperature compensation for accurate measurements over the full scale.

• Automatic calibration reminder to remind the user to calibrate the meter regularly.

• Automatic endpoint locking retains stable measured values for easy browsing or recording.

Calcium Ion Meter

• mV measurement mode to calculate the electrode range to ensure the accuracy of the measurement.

• The system menu can customize the number of calibration points, ion concentration units, stability standards, data lock mode, and auto-shutdown modeand other 8 functional parameters.

• One-key Reset, which automatically restores the meter to factory default settings.

• Extended memory for up to 500 sets of measurement data.

• Built-in clock automatically marks the date and time of stored data to comply with GLP specifications.

• USB communication interface to send stored data to a personal computer.

Bante931 column parameter model table

ModelMeasurement parametersRange
Bante931-NH4ammonium5x10-6~1mol/L
Bante931-Brbromine5x10-6~1mol/L
Bante931-Cacalcium5x10-7~1mol/L
Bante931-CLchlorine5x10-6~1mol/L
Bante931-Cncyanogen5x10-6~0.01mol/L
Bante931-Ffluorine1x10-6mol/L~saturated
Bante931-NO3Nitrate7x10-6~1mol/L
Bante931-Agsilver1x10-7~1mol/L
Bante931-Nasodium1x10-5~1mol/L
Bante931-Cdcadmium1x10-6~0.1mol/L
Bante931-Cucopper1x10-8~0.1mol/L
Bante931-Iiodine5x10-8~1mol/L
Bante931-Pblead1x10-8~0.1mol/L
Bante931-Kpotassium1x10-6~1mol/L
Bante931-Ssulfur1x10-7~1mol/L
Bante931-NH3ammonia1x10-6~1mol/L