BANTE A150-UK Laboratory conductivity /TDS/salinity/resistivity meter

SE
Import electrode, while detecting conductivity, TDS, salinity, resistivity value, including 5 measurement functions, 1000 sets of data storage, automatic temperature compensation, with calibrated reminder function.
$626.00/set
PromotionLoading...
Coupon
Model:
Certificate

Bante A150-UK Laboratory conductivity /TDS/salinity/resistivity meterSPEC

Bante A150-UK Laboratory conductivity /TDS/salinity/resistivity meterDetails

Bante A150-UK Laboratory conductivity /TDS/salinity/resistivity meterPacking list

SKU
NB014813
Measuring range
0.01~20mS/cm
resolution
0.001, 0.01, 0.1, 1
Conductivity Detector measurement Accuracy
±0.5% F.S
Conductivity Detector calibrated point
1 to 3 point
Calibrating fluid
10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
TDS range
0~10ppt (Max. 20ppt)
TDS measurement Accuracy
±1% F.S.
TDS conversion factor
0.01~ 1.00 (default 0.5)
Salinity range
0~10pp
Salinity range
±1% F.S
Salinity measurement mode
Practical salinity (psu), seawater salinity (ppt),% salinity
Resistivity Measurement range
0 ~ 10MZ
Resistivity measurement Accuracy
±1% F.S
Resistivity display resolution
0.01, 0.1, 1
Conductivity Detector ash Measurement range
0.00~100%
Conductivity Detector ash measurement Accuracy
±1% F.S
Conductivity Detector ash measurement mode
Refined or jagged sugar
Temperature Measurement range
0~105℃
Temperature measurement Accuracy
±0.5℃
Temperature display resolution
0.1℃
Temperature calibrating point
1 point
Temperature unit
℃/℉
Temperature compensation range
0~100℃
Temperature compensation mode
Linear, nonlinear or pure water compensation
Standardized temperature
20 ℃, 25 ℃, optional
Conductivity Detector cell constant
Two-ring electrode (K = 0.1, 1, 10) or four-ring electrode
Data stability condition
Standard or high precision
Interval reading
10, 30, 60 seconds, 10, 30 minutes or off
Calibrated reminder
1 to 31 days or closed
data storage
1000 groups
Data Interface
USB
Connector
6-Pin MINI Connector
Display
7-Inch TFT LCD
Power
DC12V power adapter
Dimensions
240*200*80mm
Weight
1.7kg
Optional accessories
TP-10K Temperature Probe, Conductivity Detector
Packaging Dimensions
300*240*170mm
Encasement Weight
2kg
Temperature compensation method
Manual/Automatic
A150-UK
Laboratory conductivity /TDS/salinity/resistivity meter
Import electrode, while detecting conductivity, TDS, salinity, resistivity value, including 5 measurement functions, 1000 sets of data storage, automatic temperature compensation, with calibrated reminder function.
BANTE A150-UK Laboratory conductivity /TDS/salinity/resistivity meter Picture

A150 LABOratory Conductivity/TDS/Salinity/Resistivity/Conductivity Ash Meter

Professional laboratory conductivity meter, including 5 measurement functions, 1000 sets of data storage, the meter is suitable for measuring liquid conductivity, total dissolved solids (TDS), salinity, resistivity and conductivity ash value, measurement accuracy: 0.5 %FS.

Features

• Professional laboratory conductivity meter with 7-inch TFT display.

• 1 to 5 point key calibration, automatic identification of conductivity standard solution.

• Selectable cell constants to match connected conductivity electrodes and recall calibration data for each sensor.

• Optional linear temperature compensation coefficient, pure water compensation coefficient, normalized temperature and TDS conversion factor.

LABOratory Conductivity Meter

LABOratory Conductivity Meter


• Automatic temperature compensation to ensure accurate measurement over the full range.

• Alarm limit, automatically warns if the measured value exceeds the set range.

• Calibration due reminder to remind users to calibrate the meter regularly.

• Automatic end point locking, retaining stable measurement values for easy viewing and recording.

• Interval reading mode, regularly send measured values to PC or printer.

• Password protection to prevent unauthorized calibration and settings.

• Expanded memory can store up to 1000 sets of data.

• USB communication interface is easy to connect external devices.

• One key reset (Reset) automatically restores the instrument to the factory default settings.