- SKU
- NB014825
- pH Measurement range
- -2.000~20.000pH
- pH measurement Accuracy
- ±0.002pH
- pH resolution
- 0.1, 0.01, 0.001pH, optional
- pH calibrating point
- 1 to 5 point
- pH calibrating solution
- USA, NIST, DIN, custom
- pH temperature compensation range
- 0~100°C, 32~212°F
- pH temperature compensation
- Manual/Automatic
- ORP Measurement range
- ±1999.9mV
- mV measurement Accuracy
- ±0.2mV
- mV resolution
- 0.1, 1mV, optional
- Conductivity Detector Measurement range
- 0~20mS/cm (最大 200mS/cm)
- 电导率Accuracy
- ±0.5%FS
- Conductivity Detector resolution
- 0.001, 0.01, 0.1, 1
- Conductivity Detector calibrated point
- 1 to 5 point
- Conductivity Detector using calibrating fluid
- 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
- Temperature compensation range
- 0~100℃, 32~212°F
- Temperature compensation method
- Manual or automatic
- temperature compensation coefficient
- 0.0~10.0%/°C
- Temperature compensation mode
- Linear or pure water
- Conductivity Detector cell constant
- K = 0.1, 1, 10, custom
- Standardized temperature
- 20 ℃, 25 ℃, optional
- TDS range
- 0 to 10ppt (up to 200ppt)
- TDSAccuracy
- ±1%FS
- TDS conversion factor
- 0.1~ 1.0 (default 0.5)
- Temperature Measurement range
- 0~105℃, 32~221℉
- Temperature measurement Accuracy
- ±0.5℃
- temperature resolution
- 0.1℃
- Temperature calibrating point
- 1 point
- Temperature unit
- ℃, ° F, optional
- Data stability condition
- Fast or high precision
- Calibrated reminder
- 1 to 31 days or closed
- shutdown mode
- Manual or automatic (10, 20, 30 minutes after no button operation)
- data storage
- 500 groups
- Communication interface
- USB
- Connector
- BNC, 6-pin MINI Connector
- Display
- Customized LCD (130 * 110mm)
- Power
- DC5V power adapter
- Dimensions
- 210*188*60mm
- Instrument Weight
- 1.5kg
- Optional accessories
- P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode,
- Optional accessories
- P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode,
- Optional accessories
- Type 501 ORP electrode, Type 502 ORP electrode, CON-0.1 electrode, Conductivity Detector standard solution, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard), TP-10K temperature probe
- Packaging Dimensions
- 300*240*170mm
- Encasement Weight
- 1.7kg
Bante901-UK
Precision pH/Conductivity Meter
With import electrode, pH Measurement range -2.000~20.000pH, conductivity Measurement range 0~20mS/cm, Automatic temperature compensation, Automatic calibration reminder.
Bante901 Precision pH/Conductivity Meter
Multi-parameter laboratory pH meter, including 4 measurement functions, 12 functional parameters can be customized in the built-in system menu, the meter is suitable for measuring pH, mV, conductivity and total dissolved solids (TDS) value of liquids.
pH mode features:
• Multi-parameter Water Quality Analyzer with large backlit LCD display.
• 1 to 5 point key calibration, automatic identification of pH standard buffer.
• Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.
• Automatic electrode slope display, prompting the user whether to replace the pH electrode.
Conductivity/TDS mode features:
• 1 to 5 point key calibration, automatic identification of conductivity standard solution.
• Optional cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation modes.

laboratory pH meter
General features:
• Automatic temperature compensation to ensure accurate measurement over the full range.
• Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.
• Automatic end point locking, retaining stable measurement values for easy viewing and recording.
• Automatic electrode diagnosis, you can check the zero offset, electrode slope and conductivity K value.
• The system menu can customize 12 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.
• One key reset (Reset) automatically restores the instrument to the factory default settings.
• Expanded memory can store up to 500 sets of measurement data.
• The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.
• USB communication interface to send stored data to PC.
Packing list:Host X1, P11 type pH electrode (made in the UK) X1, K10 type Conductivity detector electrode (made in the UK) X1, TP-10K type temperature probe X1, pH standard buffer reagent (pH4.01/7.00/10.01) X1, Conductivity detector standard solution (84uS/cm, 1413uS/cm, 12.88mS/cm) X1, USB cable X1, DC5V power adapter X1, manual X1, certificate X1, warranty card X1
[Note]Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.