China

Bante902-CN Precision pH/conductivity /TDS/salinity/resistivity meter

SE
Simultaneously detect pH, conductivity, TDS, salinity, with China electrode, automatic temperature compensation, calibrated reminder, end point locking, support 500 sets of measurement data.
$509.00/set
PromotionLoading...
Coupon
Model:
Certificate

Bante Bante902-CN Multiparameter Water Quality AnalyzerSPEC

Bante Bante902-CN Multiparameter Water Quality AnalyzerDetails

Bante Bante902-CN Multiparameter Water Quality AnalyzerPacking list

SKU
NB014826
Measurement range of pH
-2.000~20.000pH
Measurement Accuracy of pH
±0.002pH
Measurement Accuracy of pH
0.1, 0.01, 0.001 pH, optional
pH calibrating point
1 to 5 points
pH calibrating solution
USA, NIST, DIN, Custom
pH temperature compensation range
0~100℃
pH temperature compensation
Manual/Automatic
ORP Measurement range
±1999.9mV
mV Measurement Accuracy
±0.2mV
mV resolution
0.1/1 mV, optional
mV calibrating point
1 point (for R.mV mode only)
mV calibrated range
±200mV
EC Measurement range
0~ 20mS/cm (max. 200mS/cm)
EC Measurement Accuracy
±0.5%FS
EC resolution
0.001, 0.01, 0.1, 1
EC calibrating point
1 to 5 points
Use calibrating fluid
10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
EC temperature compensation range
0~100℃, 32~212°F
EC temperature compensation
Manual or automatic
EC temperature compensation coefficient
0.0~10.0%/℃
EC temperature compensation mode
Linear or pure water
Conductivity Detector cell constant
K = 0.1, 1, 10, custom
Standardized temperature
20 ℃, 25 ℃, optional
TDS Measurement range
0~ 10ppt (max 200ppt)
TDS Measurement Accuracy
±1%FS
TDS conversion factor
0.1~ 1.0 (default 0.5)
Measurement range of salinity
0~ 10ppt (maximum 80ppt)
Measurement Accuracy of salinity
±1%FS
Measurement mode of salinity
Utility salinity (psu) or seawater salinity (ppt)
Measurement range of resistivity
0~ 10MΩ (up to 20MΩ)
Measurement Accuracy of resistivity
±1%FS
Resistivity resolution
0.01, 0.1, 1
Measurement range
0~105℃, 32~221℉
Measurement Accuracy
±0.5℃
Temperature Resolution
0.1℃
Temperature calibrating point
1 point
Temperature unit
° C, ° F, optional
Data stability condition
Fast or high-precision
Calibrated reminder
1 to 31 days or closed
shutdown mode
Manual or automatic (10, 20, 30 minutes after no button operation)
Data storage
500 sets
Communication interface
USB
Connector
BNC, 6-pin MINI Connector
Display
Customized LCD screen (130 * 110mm)
Power Supply
DC5V power adapter
Dimension
210*188*60mm
instrument Weight
1.5kg
Optional Accessories
P19 type pH electrode, P18 type pH electrode, P16 type pH electrode, P15 type pH electrode, P13 type pH electrode, P12 type pH electrode, P11 type pH electrode, P11-LiCl type pH electrode, P11 type pH electrode, P11-NA type pH electrode,
Optional Accessories
TP-10K temperature probe, pH standard buffer reagent (NIST standard), pH standard buffer reagent (USA standard), Conductivity Detector standard solution, CON-10 type Conductivity Detector electrode, CON-1 type Conductivity Detector electrode, CON-0.1 type Conductivity Detector electrode, P21 type pH electrode, P22 type pH electrode, 501 type ORP electrode, 502 type ORP electrode
Packaging Dimensions
300*240*170mm
Encasement Weight
1.7kg
Bante902-CN
Multiparameter Water Quality Analyzer
Simultaneously detect pH, conductivity, TDS, salinity, with China electrode, automatic temperature compensation, calibrated reminder, end point locking, support 500 sets of measurement data.
Bante902-CN Precision pH/conductivity /TDS/salinity/resistivity meter Picture

Bante902 Precision pH/Conductivity/TDS/Salinity Meter

Multi-parameter laboratory pH meter, including 6 measurement functions, built-in system menu can customize 12 functional parameters, the meter is suitable for measuring liquid pH, redox potential, conductivity, total dissolved solids, salinity and resistivity values .

pH mode features:

• Multi-parameter Water Quality Analyzer with large backlit LCD display.

• 1 to 5 point key calibration, automatic identification of pH standard buffer.

• Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.

• Automatic electrode slope display, prompting the user whether to replace the pH electrode.

ORP mode features:

• 1-point offset calibration, allowing adjustment of displayed values to known standards.

• Relative and absolute mV modes provide accurate ORP readings.

laboratory pH meter

laboratory pH meter

Conductivity/TDS/salinity/resistivity mode features:

• 1 to 5 point key calibration, automatic identification of conductivity standard solution.

• Selectable cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation, seawater and practical salinity measurement modes.

General features:

• Automatic temperature compensation to ensure accurate measurement over the full range.

• Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.

• Automatic end point locking, retaining stable measurement values for easy viewing and recording.

• Automatic electrode diagnosis, you can check the zero offset, electrode slope and conductivity K value.

• The system menu can customize 12 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.

• One key reset (Reset) automatically restores the instrument to the factory default settings.

• Expanded memory can store up to 500 sets of measurement data.

• The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.

• USB communication interface to send stored data to PC.