Bante903-UK precision pH/Dissolved Oxygen Meter

SE
Measurement of liquid pH, Oxidation-reduction potential, dissolved oxygen concentration and saturation. -2.000~20.000pH, +/- 1999.9mV, 0.00~20.00mg/L, 0~105 ℃.
$607.00/set
PromotionLoading...
Coupon
Model:
Certificate

Bante Bante903-UK Precision pH/Dissolved Oxygen MeterSPEC

Bante Bante903-UK Precision pH/Dissolved Oxygen MeterDetails

Bante Bante903-UK Precision pH/Dissolved Oxygen MeterPacking list

SKU
NB014829
pH Measurement range
-2.000~20.000pH
pH measurement Accuracy
±0.002pH
pH resolution
0.1, 0.01, 0.001pH, optional
pH calibrating point
1 to 5 point
pH calibrating solution
USA, NIST, DIN, custom
pH temperature compensation range
0~100°C, 32~212°F
pH temperature compensation
Manual/Automatic
ORP Measurement range
±1999.9mV
mV measurement Accuracy
±0.2mV
mV resolution
0.1, 1mV, optional
mV calibrated point
1 point (only for R.mV mode)
mV calibrated range
±200mV
DO range
0.00~20.00mg/L
DO measurement Accuracy
±0.2mg/L
DO resolution
0.1, 0.01 mg/L, optional
DO temperature compensation range
0~50℃
DO temperature compensation
automatic
Pressure compensation range
60.0~112.5kPa, 450~850mmHg
Salinity compensation range
0~50g/L
DO% Measurement range
0.0~200.0%
DO% measurement Accuracy
±2.0%
DO% resolution
0.1%
Temperature Measurement range
0~105℃, 32~221℉
Temperature measurement Accuracy
±0.5℃
temperature resolution
0.1℃
Temperature calibrating point
1 point
Temperature unit
℃, ° F, optional
Data stability condition
Fast or high precision
Calibrated reminder
1 to 31 days or closed
shutdown mode
Manual or automatic (10, 20, 30 minutes after no button operation)
data storage
500 groups
Communication interface
USB
Connector
BNC, 6-pin MINI Connector
Display
Customized LCD (130 * 110mm)
Power
DC5V power adapter
Dimensions
210*188*60mm
Instrument Weight
1.5kg
Optional accessories
P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode, P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode
Optional accessories
TP-10K temperature probe, dissolved Oxygen electrode film cap, dissolved Oxygen electrode filler, pH standard buffer reagent (NIST standard), pH standard buffer reagent (USA standard), P19 type pH electrode, P21 type pH electrode, P22 type pH electrode, DO100 type dissolved Oxygen electrode,
Packaging Dimensions
300*240*170mm
Encasement Weight
1.7kg
Bante903-UK
Precision pH/Dissolved Oxygen Meter
Measurement of liquid pH, Oxidation-reduction potential, dissolved oxygen concentration and saturation. -2.000~20.000pH, +/- 1999.9mV, 0.00~20.00mg/L, 0~105 ℃.
Bante903-UK precision pH/Dissolved Oxygen Meter Picture

Bante903 Precision pH/Dissolved Oxygen Meter

Multi-parameter laboratory pH meter, including 3 measurement functions, the built-in system menu can customize 11 function parameters, the meter is suitable for measuring the pH, redox potential, dissolved oxygen concentration and saturation of liquids.

pH mode features:

• Multi-parameter Water Quality Analyzer with large backlit LCD display.

• 1 to 5 point key calibration, automatic identification of pH standard buffer.

• Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.

• Automatic electrode slope display, prompting the user whether to replace the pH electrode.

ORP mode features:

• 1-point offset calibration, allowing adjustment of displayed values to known standards.

• Relative and absolute mV modes provide accurate ORP readings.

laboratory pH meter

laboratory pH meter

Functional characteristics of dissolved oxygen mode:

• 1 or 2 point pushbutton calibration using air saturated water or zero oxygen liquid.

• Compensation for salinity and atmospheric pressure to improve the measurement accuracy of the instrument.

General features:

• Automatic temperature compensation to ensure accurate measurement over the full range.

• Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.

• Automatic end point locking, retaining stable measurement values for easy viewing and recording.

• Automatic electrode diagnosis, you can check the zero offset and electrode slope.

• The system menu can customize 11 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.

• One key reset (Reset) automatically restores the instrument to the factory default settings.

• Expanded memory can store up to 500 sets of measurement data.

• The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.

• USB communication interface to send stored data to PC.

FAQ
QWhat does cn mean after STIP-scan?
A With China electrode, UK is with the import electrode.
QHow to calibrate STIP-scan temperature?
A Specific operations: 1. Ensure that the temperature probe is connected to the meter; 2. Press and hold the ℃ key for 3 seconds, the meter enters the temperature calibrate mode, and the screen displays the current temperature value; 3. Press up or down to set the temperature value; 4. Press the enter key to confirm, the calibrate is complete.
QThe screen displays --- what is the reason?
A There are two possible reasons: 1. The electrode Sensors are too drying, which can be solved by immersing in tap water for 10 minutes; 2. Measured value Excessive range: Check whether the Sensors are clean and not contaminated.
Standard