- SKU
- NB014830
- Conductivity range
- 0~20mS/cm (max. 200mS/cm)
- Measurement Accuracy of conductivity
- ±0.5%FS
- EC resolution
- 0.001, 0.01, 0.1, 1
- Conductivity calibrated point
- 1 to 5 point
- Use calibrating fluid
- 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
- EC Temperature Compensation Range
- 0~100℃, 32~212°F
- EC Temperature Compensation Mode
- Manual or automatic
- EC Temperature Compensation Coefficient
- 0.0~10.0%/℃
- EC Temperature Compensation Mode mode
- Linear or pure water
- Conductivity Detector cell constant
- K = 0.1, 1, 10, custom
- Standardized temperature
- 20 ℃, 25 ℃, optional
- TDS range
- 0~10ppt (max 200ppt)
- TDS Measurement Accuracy
- ±1%FS
- TDS conversion factor
- 0.1~ 1.0 (default 0.5)
- Salinity range
- 0~10ppt (max 80ppt)
- Measurement Accuracy of salinity
- ±1%FS
- Measurement mode of salinity
- Utility salinity (psu) or seawater salinity (ppt)
- Resistivity range
- 0~10MΩ (up to 20MΩ)
- Measurement Accuracy of resistivity
- ±1%FS
- Resistivity resolution
- 0.01, 0.1, 1
- DO range
- 0.00~20.00mg/L(ppm)
- DO Measurement Accuracy
- ±0.2mg/L
- DOS resolution
- 0.1, 0.01 mg/L, optional
- Temperature compensation range
- 0~50℃, 32~122°F
- Temperature compensation method
- automatic
- Pressure compensation range
- 60.0~112.5kPa, 450~850mmHg
- Salinity compensation range
- 0~50g/L
- Measurement range
- 0~105℃, 32~221℉
- Measurement Accuracy
- ±0.5℃
- Temperature Resolution
- 0.1℃
- Temperature calibrating point
- 1 point
- Temperature unit
- ℃, ° F, optional
- Data stability condition
- Fast or high-precision
- Calibrated reminder
- 1 to 31 days or closed
- shutdown mode
- Manual or automatic (10, 20, 30 minutes after no button operation)
- Data storage
- 500 sets
- Communication interface
- USB
- Connector
- 6-Pin MINI Connector
- Display
- Customized LCD screen (130 * 110mm)
- Power Supply
- DC5V power adapter
- Dimension
- 210*188*60mm
- instrument Weight
- 1.5kg
- Optional Accessories
- TP-10K temperature probe, dissolved Oxygen electrode film cap, dissolved Oxygen electrode filling solution, Conductivity Detector standard solution, CON-0.1 type Conductivity Detector electrode, CON-1 type Conductivity Detector electrode, CON-10 type Conductivity Detector electrode, DO100 type dissolved Oxygen electrode
- Packaging Dimensions
- 300*240*170mm
- Encasement Weight
- 1.7kg
Bante904-CN
Precision pH/conductivity /TDS/salinity/resistivity meter
CHINA electrode, while detecting pH, conductivity, TDS, salinity, resistivity, automatic temperature compensation, calibrating reminder, end point locking, electrode diagnosis.
Bante904 precision conductivity/TDS/salinity/Dissolved Oxygen Meter
Multi-parameter laboratory TDS meter, including 5 measurement functions, built-in system menu can customize 13 function parameters, the meter is suitable for measuring liquid conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation.
Conductivity/TDS/salinity/resistivity mode features:
• Multi-parameter Water Quality Analyzer with large backlit LCD display.
• 1 to 5 point key calibration, automatic identification of conductivity standard solution.
• Selectable cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation,
Seawater and practical salinity measurement modes.
Functional characteristics of dissolved oxygen mode:
• 1 or 2 point pushbutton calibration using air saturated water or zero oxygen liquid.
• Compensation for salinity and atmospheric pressure to improve the measurement accuracy of the instrument.

TDS meter
General features:
• Automatic temperature compensation to ensure accurate measurement over the full range.
• Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.
• Automatic end point locking, retaining stable measurement values for easy viewing and recording.
• Automatic electrode diagnosis, you can check the electrode slope value (K).
• The system menu can customize 13 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.
• One key reset (Reset) automatically restores the instrument to the factory default settings.
• Expanded memory can store up to 500 sets of measurement data.
• The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.
• USB communication interface to send stored data to PC.
Packing list:Host X1, Con-1 type Conductivity detector electrode X1, DO100 type dissolved Oxygen electrode (made in the United States) X1, TP-10K type temperature probe X1, Conductivity detector standard solution (84uS/cm, 1413uS/cm, 12.88mS/cm) X1, dissolved Oxygen electrode filling solution X1, dissolved Oxygen electrode film cap X1, USB cable X1, DC5V power adapter X1, manual X1, certificate X1, warranty card X1
[Note]Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.