China

Bante TB100 portable Turbidity Meter

SE
High performance portable Turbidity Meter, 2 to 5 point calibrated, optional 4 Measurement units, instrument with single and continuous Measurement mode, suitable for process control and outdoor applications.
$347.00/set
PromotionLoading...
Coupon
Model:
Certificate

Bante TB100 Portable Turbidity MeterSPEC

Bante TB100 Portable Turbidity MeterDetails

Bante TB100 Portable Turbidity MeterPacking list

SKU
NB014835
Measurement method
ISO 7027 nephelometric method (90°)
Measuring range
0 ~ 1100 NTU / FNU, 0 ~ 275EBC, 0 ~ 9999 ASBC
resolution
0.01 (0~100 NTU), 0.1 (100~999 NTU), 1 (999~1100 NTU)
Accuracy
±2% (0~500 NTU), ±3% (501~1100 NTU)
Default calibrated point
0.02, 10.00, 200, 500, 1000 NTU
Light source/wavelength
Infrared Light Emitting Diodes
Receiving element
Silicon photoelectric receiver
stray light
< 0.02 NTU
Colorimetric bottle
60 (H) × 25 (D) mm
shutdown mode
Manual or automatic (15 minutes after no button operation)
Data storage
100 groups
Communication interface
USB
Operating temperature
0~60°C
Power
9V laminated battery 1
Dimensions
180*85*70mm
Instrument net Weight
300g
Optional accessories
Suitable for TB series turbidity meter
Packaging Dimensions
280 (L) × 230 (W) × 80 (H) mm
Encasement Weight
1.5kg
TB100
Portable Turbidity Meter
High performance portable Turbidity Meter, 2 to 5 point calibrated, optional 4 Measurement units, instrument with single and continuous Measurement mode, suitable for process control and outdoor applications.
Bante TB100 portable Turbidity Meter Picture

TB100 Portable Turbidimeter

High-performance portable Turbidimeter, 2 to 5-point calibration, 4 measurement units can be selected, the meter has single and continuous measurement modes, suitable for process control and outdoor applications.

Features

• Easy-to-use portable turbidimeter with standard carrying case.

• For 2 to 5 point calibration, use formazin standard solution.

• Optional 4 turbidity units, including NTU (Scattering Turbidity Units), FNU (Formazin Scattering Units), EBC (European Brewers

  Association unit) and ASBC (American Brewers Association unit).

• Single measurement mode automatically determines stable readings.

• Continuous measurement mode can be used for indexing or pairing cuvettes.

Portable Turbidimeter

Portable Turbidimeter


• Automatic power off, effectively saving battery power consumption.

• Built-in system menu, which can customize 7 functional parameters such as the number of calibration points, date and time, and display resolution.

• One-button reset, automatically restore the instrument to factory default settings.

• Expanded memory can store up to 100 sets of measurement data.

• USB communication interface to send stored data to PC.

• Multi-mode power supply scheme (power adapter, computer USB port) ensures the smooth application of the instrument.


FAQ
QWhether the clearer the turbidity meter is, the easier the light is to pass through, and the smaller the data. The more turbid, the less likely the light will be transmitted, and the larger the data? It has nothing to do with whether the liquid itself has Color
A Turbidity meters measure the transparency or light transmittance of a liquid, not the Color of the liquid. Therefore, turbidity is independent of the Color of the liquid. In a turbidity meter, light is affected by scattering and absorption when it passes through a liquid. When there are more suspended particles, dissolved substances, or bubbles in the liquid, the rays of light are scattered by these particles, so that the intensity of the ray of light measured from the other end decreases and the turbidity value increases. In other words, the higher the turbidity value, the more particles in the liquid, the worse the light transmission, and the greater the hindrance to the transmission of the ray of light through the liquid. Therefore, for the turbidity meter, the lower the turbidity value, the clearer the liquid and the better the light transmittance, while the higher the turbidity value, the more turbid the liquid and the worse the light transmittance. This has nothing to do with the Color of the liquid, but mainly depends on the concentration and size of suspended particles, dissolved substances or bubbles in the liquid.
QIs this turbidity meter available in EBC units?
A The TB100 portable turbidity meter can choose 4 turbidity units, including NTU, FNU, EBC and ASBC, and the default unit is NTU.
QDoes the portable turbidity meter meet the specifications of ISO15715?
A Model TB100 Portable turbidity meter
Standard