XINRUI WGZ-2B Turbidity Meter range 0~10/100/500NTU

XINRUI WGZ-2B is a portable Turbidity Meter with a Measurement range of 0~10, 0~100, 0~500 and a minimum indication (NTU) of 0.001. The WGZ-2B Turbidity Meter can be manually selected or automatically switched measurement range.
Model:

XinRui WGZ-2B Turbidity MeterSPEC

XinRui WGZ-2B Turbidity MeterDetails

XinRui WGZ-2B Turbidity MeterPacking list

SKU
NB015031
Measurement principle
90 ° scattered light
type
Portable
Resolution
0.001
Measurement range
0~10NTU、0~100NTU、0~500NTU
Error of indication
±6%(±2%F.S)
Repeatability
±0.5%F.S
Zero drift
±0.5%F.S
Power supply Voltage
DC 1.5V × 5 AA alkaline dry batteries, AC 220V/50Hz/DC7.5V/0.2A power adapter
WGZ-2B
Turbidity Meter
XINRUI WGZ-2B Turbidity Meter range 0~10/100/500NTU Picture

Overview of uses 

The SignRich WGZ-2B Turbidity Meter is used to measure the degree of light scattering produced by insoluble particulate matter suspended in water or transparent liquids, and to quantitatively characterize the amount of these suspended particulate matter. It can be widely used in turbidity measurement of power plants, pure water plants, water plants, domestic (CN) sewage treatment plants, beverage plants, environmental protection departments, industrial water, wine industry and industries, departments, and other departments.

Xinrui WGZ-2B Turbidity Meter

Features 

  1. Portable, AC and DC power supply, with low Voltage indication and automatic shutdown function. The serial RS232 communication interface can be used to connect to micro printers.

  2. The microcomputer is equipped with a low-power configuration and a touch-screen keyboard with a backlit LCD display that simultaneously displays the date, time, measured value and unit of measurement.

  3. The measuring range can be manually selected or automatically switched. The calibration standard value can be set arbitrarily programmable, and 1-7 points can be quickly and arbitrarily selected for automatic correction.

  4. It is equipped with an average measurement mode and a data query mode, with the functions of nonlinear processing and smoothing of measurement data, and with self-diagnosis information prompts.

  5. The built-in clock memory storage system can store measurement and calibration data in real time, and can store and recall the last 20 sets of measurement data for a long time.

  6. A variety of measurement modes, preset NTU, FTU, EBC, degree (Unit), ppm, mg/L, % and other units.

  7. It is equipped with a color compensation system, which can effectively avoid the interference caused by the color of the sample and can correctly reflect the concept of turbidity.

  8. 100,000 hours long-life high-intensity light source, maintenance-free long-term use, in line with ISO turbidity measurement standards.

Serial models


ModelWGZ-500BWGZ-2BWGZ-3BWGZ-4000B
Determination principle90° scattered light90° scattered light90° scattered light90° scattered light
typeportableportableportableportable
Minimum Indicative Value (NTU)0.010.0010.010.01
Measuring Range (NTU)0~50,0~5000~10,0~100,0~5000~10,0~100,0~10000~10,0~100,0~1000,0~4000
Indication error±6%(±2%F.S)±6%(±2%F.S)±6%(±2%F.S)±6%(±2%F.S)
repeatability≤0.5%≤0.5%≤0.5%≤0.5%
Zero drift±0.5%F.S±0.5%F.S±0.5%F.S±0.5%F.S
FeaturesMicrocomputer configuration, with average measurement mode, year, month, day and time display, with data storage and query function, automatic range switching, automatic zero adjustment and 1~5 point automatic calibration, equipped with RS232 data communication interface, can be equipped with external micro printerMicrocomputer configuration, with average measurement mode, year, month, day and time display, with data storage and query function, automatic range switching, automatic zero adjustment and 1~5 point automatic calibration, equipped with RS232 data communication interface, can be equipped with external micro printerMicrocomputer configuration, with average measurement mode, year, month, day and time display, with data storage and query function, automatic range switching, automatic zero adjustment and 1~5 point automatic calibration, equipped with RS232 data communication interface, can be equipped with external micro printerMicrocomputer configuration, with average measurement mode, year, month, day and time display, with data storage and query function, automatic range switching, automatic zero adjustment and 1~5 point automatic calibration, equipped with RS232 data communication interface, can be equipped with external micro printer
Power supplyDC 1.5V×5 AA alkaline dry battery AC 220V/50Hz/DC7.5V/ 0.2A power adapterDC 1.5V×5 AA alkaline dry battery AC 220V/50Hz/DC7.5V/ 0.2A power adapterDC 1.5V×5 AA alkaline dry battery AC 220V/50Hz/DC7.5V/ 0.2A power adapterDC 1.5V×5 AA alkaline dry battery AC 220V/50Hz/DC7.5V/ 0.2A power adapter