China

JINGKELIAN QMB minimum film forming temperature (MFFT) Tester, stainless steel profiled temperature layer

SE
Operating temperature range of layer plate -7~ 70 ℃, temperature measurement point 13 points, layer interval 20mm, test Coating tank 6, inspection table shows 16 points, of which 1~ 13 points for the working layer temperature, 14 points for the instrument Environmental temperature, 15, 16 points for the chilled down water inlet and outlet temperature, standard GB9267-88.
$2835.00/set
PromotionLoading...
Coupon
Model:
Certificate

JingKeLian QMB Minimum film forming temperature (MFFT) TesterSPEC

JingKeLian QMB Minimum film forming temperature (MFFT) TesterDetails

JingKeLian QMB Minimum film forming temperature (MFFT) TesterPacking list

SKU
NB001527
Layer operation temperature range
-7~70℃
Temperature measurement point
13 point
Layer spacing
20mm
Test Coating Tank
6 strips, length 240mm, width 22mm (national standard 20~25mm), depth 0.25mm (national standard 0.20~ 0.30mm)
Inspection form display
16 point, of which 1 to 13 point is the working layer temperature, 14 point is the instrument environment temperature, 15 and 16 point are the inlet and outlet temperature of the chilled down water
standard
GB9267-88
QMB
Minimum film forming temperature (MFFT) Tester
Operating temperature range of layer plate -7~ 70 ℃, temperature measurement point 13 points, layer interval 20mm, test Coating tank 6, inspection table shows 16 points, of which 1~ 13 points for the working layer temperature, 14 points for the instrument Environmental temperature, 15, 16 points for the chilled down water inlet and outlet temperature, standard GB9267-88.
JINGKELIAN QMB minimum film forming temperature (MFFT) Tester, stainless steel profiled temperature layer Picture

Overview of QMB Minimum Film Formation Temperature Meter

JinKeLian QMB minimum film-forming temperature measuring instrument is designed according to the national standard GB9267-88. It adopts platinum resistance imported from Germany as the temperature sensor, and adopts the LU-906M intelligent temperature regulator combined with fuzzy control theory and PID control to ensure the display The error is less than 0.5%±1 word. The remarkable feature of the QMB Minimum Film Forming Temperature Meter is the use of a stainless steel special-shaped temperature gradient plate with a temperature adjustment range of -7°C to 70°C.

Advantages of QMB Minimum Film Forming Temperature Meter

1. Desktop energy saving

2. The temperature sensor adopts platinum resistance imported from Germany, and the LU-906M intelligent temperature regulator combined with fuzzy control theory and PID control, and the display error is less than 0.5%±1 character.

3. The temperature gradient plate is a stainless steel special-shaped temperature gradient plate. The main components are the temperature control system (intelligent temperature regulator, high-precision temperature sensor, switching power supply, semiconductor refrigeration device), inspection system, drying device and corresponding electrical control circuit.

4. Professional semiconductor refrigeration and high-power regulated switching power supply reduce the noise of the refrigeration system.

5. The measuring instrument is equipped with a water cut-off

6. The cooling water temperature is displayed (at the 15th and 16th points of the inspection table), and the water flow is minimized (manually) according to different setting conditions.

7. There are obvious subdivision scales on the front and back of the workbench, which is convenient for accurate judgment of MFT .

Display of QMB Minimum Film Forming Temperature Meter

JinKeLian QMB Minimum Film Forming Temperature Meter Appearance

FAQ
QHow many degrees Celsius can your film formation tester achieve?
A Hello, the temperature range is -7 ℃~ 70 ℃.
QI want to do a test about the GB/T9267 standard. Is this minimum film forming temperature (MFFT) meter okay?
A Sure
QDoes the Spreader emulsion need to fill the test tank when using this minimum film forming temperature (MFFT) meter?
A Hello, it is not necessary to cover the test tank, as long as it is coated around the estimated MFT, which saves labor and is easy to clean.
QQMB test emulsion paint how to determine the minimum film forming temperature (MFFT) point?
A Hello, the QMB minimum film forming temperature (MFFT) tester tests emulsion paint. After the emulsion water evaporates, the polymer molecules interact to form a continuous film at an appropriate temperature. The part of the film formation higher than the emulsion MFT is transparent, and the part lower than the MFT is checking or chalk. This obvious dividing line is the minimum film forming temperature (MFFT) of the emulsion.
QWhat are the power requirements for this QMB minimum film forming temperature (MFFT) meter?
A Hello, it requires 220 volts, 50Hz, > 400W, three-hole socket, and good grounding.
QWhat is the minimum film forming temperature (MFFT) range?
A Hello, the QMB minimum film forming temperature (MFFT) measuring instrument shaped layer plate temperature range of -7 ℃~ 70 ℃.
Standard