- SKU
- NB016092
- Detect gas
- EX
- Range
- 0~100%LEL
- resolution
- 0.1%LEL
- Response time
- T90≤20s
- detection Accuracy
- ≤±3%
- Linearity
- ≤±1%
- Zero drift
- ≤ +/- 1% (F. S/year)
- recovery time
- ≤20s
- Repeatability
- ≤±1%
- expansion gas
- Supports 1-6 Sensors (optional)
- Explosion-proof sign
- CNEx16.0547
- Protection level
- IP65
- production license
- Guangdong 00001052 (CMC metrology authentication)
- Humidity
- Optional accessories, temperature detection range: -25~ 60 ℃, Humidity detection range: 0~95% RH
- Sampling method
- Diffusion, flow, pump suction optional
- Installation method
- Wall-mounted, pipeline, circulation
- signal output
- ① 4-20mA signal ② RS485 signal ③ Voltage signal
- signal output
- ④ Optional 4-20mA + Hart output ⑤ switching signal
- receiving device
- User computer, control alarm, PLC, DCS, mobile phone, tablet computer, etc. are optional
- Alarm mode
- On-site sound and light alarm, external alarm, remote Controller alarm, computer data collection software alarm, mobile app notification, SMS alarm optional
- Shell material
- Die casting aluminum + sand blasting oxidation/fluorocarbon paint, explosion-proof and anti-corrosion
- Operating temperature
- -30~50℃
- Environmental humidity
- 0~95% RH non-condensing
- Operating Pressure
- 0~100Kpa
- Power Supply
- 24VDC(12~30VDC)
- Dimension
- 200*149*79mm
- Weight
- 1.5Kg
- execution standard
- GB3836.1-2010、GB3836.2-2010
MOT500-EX-Y
Gas Detector
EX, range 0~100% LEL, resolution 0.1% LEL, Response time T90 ≤ 20s, detection accuracy ≤ +/- 3%, Linearity ≤ +/- 1%
Introduction
MOT500 online combustible Gas Detector is suitable for combustible gas concentration detection in various environments. It adopts imported catalytic combustion sensor and microcontroller technology, with fast response speed, high measurement accuracy, good stability and repeatability, and the performance of the whole machine ranks first Chinese professional level.
Features



Packing list:host X1, calibration cover X1, manual X1, certificate X1
[Note]Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.