China

BOSEAN BH-60-PH3 Fixed phosphating hydrogen Gas Detector 0~20ppm

SE
BOSEAN BH-60-PH3 phosphating hydrogen Gas Detector is a wall-mounted Installation method, using die-cast aluminum explosion-proof shell design, BH-60-PH3 is dedicated to testing phosphating hydrogen gas concentration, widely used in chemical, petroleum, tunnels and other environmental testing fields.
$241.00/set
PromotionLoading...
Coupon
Model:
Certificate

Bosean BH-60-PH3 Gas DetectorSPEC

Bosean BH-60-PH3 Gas DetectorDetails

Bosean BH-60-PH3 Gas DetectorPacking list

SKU
NB016154
Range
0~20Pppm (PH3 phosphating hydrogen)
resolution
0.1ppm
Alarm point
5ppm
Power Supply
DC 24V +/- 15%
error of indication
±3%FS
System power
Maximum power consumption 3W
Ambient Operating Temperature
-10~40℃
Dimensions
193*140*93mm
Explosion-proof sign
CNEx16.0449
Explosion-proof sign
Exd ⅡC T6 Gb
response time
<30s
signal output
3-Wire 4~ 20mA or 4-wire RS485
Installation method
wall mounted
Shell material
die casting aluminum
Ambient Operating Humidity
0~95% RH non-condensing
BH-60-PH3
Gas Detector
BOSEAN BH-60-PH3 Fixed phosphating hydrogen Gas Detector 0~20ppm Picture

Introduction

BH-60 fixed Gas Detector is a new type of Gas Detector developed and produced based on the company's many years of experience in gas detection. It is used to detect the concentration of flammable gases or other toxic and harmful gases in the air. When the concentration reaches or exceeds the preset alarm value The controller will send out an audible and visual alarm to remind you to take safety measures in time to prevent explosion and poisoning accidents, thereby ensuring the safety of life and property.

This product has the advantages of stable signal, high precision, quick response, long life, short polarization time, etc. It adopts industrial-grade sensor, and the instrument shell adopts explosion-proof and explosion-proof structure design. The 4-20mA standard signal or directly enters the DOS system, which can be widely used. In metallurgy, petroleum, chemical industry, municipal and other industries, it is at the professional level of similar products in CHINA.

The shell adopts a die-cast aluminum shell with a flameproof structure design. The groove design of the upper cover can lock the shell. The front of the sensor is designed as a downward structure to ensure good contact between the sensor and the gas. The cable inlet adopts an explosion-proof waterproof connector.

Baoshian BH-60-PH3 Fixed Gas Detector

Baoshian BH-60-PH3 Fixed Gas Detector

Baoshian BH-60-PH3 Fixed Gas Detector

Baoshian BH-60-PH3 Fixed Gas Detector

Baoshian BH-60-PH3 Fixed Gas Detector

Baoshian BH-60-PH3 Fixed Gas Detector

Gas parameter table

Measured gasMeasuring rangeOptional rangeresolutionalarm point
Combustible gas EX0-100%lel0-100%vol (infrared)1%lel/1%volLow: 20 High: 50
Oxygen O20-30%vol0-30%vol0.1%volLow: 19.5% High: 23.5%vol
Hydrogen sulfide H2S0-100ppm0-50/200/1000ppm1ppmLow: 10 High: 20 ppm
carbon monoxide CO0-1000ppm0-500/2000/5000ppm1ppmLow: 50 High: 150 ppm
carbon dioxide CO20-5000ppm0-1%/5%/10%vol (infrared)1ppm/0.1%volLow: 1000 High: 2000 ppm
NO0-250ppm0-500/1000ppm1ppmLow: 50 High: 150 ppm
Nitrogen dioxide NO20-20ppm0-50/1000ppm0.1ppmLow: 5 High: 10 ppm
Sulfur dioxide SO20-20ppm0-50/1000ppm0.1/1ppmLow: 5 High: 10 ppm
Chlorine CL20-20ppm0-100/1000ppm0.1ppmLow: 5 High: 10 ppm
Hydrogen H20-1000ppm0-500/2000/5000ppm1ppmLow: 50 High: 150 ppm
Ammonia NH30-100ppm0-50/500/1000ppm0.1/1ppmLow: 20 High: 50 ppm
Phosphine PH30-20ppm0-20/1000ppm0.1ppmLow: 5 High: 10 ppm
Hydrogen chloride HCL0-20ppm0-20/500/1000ppm0.1ppmLow: 5 High: 10 ppm
Chlorine dioxide CLO20-50ppm0-10/100ppm 0.1ppmLow: 5 High: 10 ppm
Hydrogen cyanide HCN0-50ppm0-100ppm0.1/0.01ppmLow: 10 High: 20 ppm
Ethylene oxide C2H4O0-100ppm0-100ppm1/0.1ppmLow: 20 High: 50 ppm
ozone0-10ppm0-20/100ppm0.1ppmLow: 2 High: 5 ppm
Formaldehyde CH2O0-20ppm0-50/100ppm1/0.1ppmLow: 5 High: 10 ppm
Hydrogen fluoride HF0-100ppm0-1/10/50/100ppm0.01/0.1ppmLow: 2 High: 5 ppm
Xylene/Toluene0-20ppm0-1/10/50/100ppm0.01/0.1ppmLow: 5 High: 10 ppm