China

DINGDING DX30A-H2 Hydrogen Gas Detector with display + sound and light alarm 0-1000ppm

DINGDING Hydrogen Gas Detector DX30A-H2 has a display screen and an acousto-optic alarm for the measurement of hydrogen gas concentration in the range of 0-1000ppm, DX30A-H2 Hydrogen Gas Detector has a high-low concentration light alarm, and the alarm concentration is adjustable.
Certificate

DINGDING DX30A-H2 (with display + sound and light alarm) Gas DetectorSPEC

DINGDING DX30A-H2 (with display + sound and light alarm) Gas DetectorDetails

DINGDING DX30A-H2 (with display + sound and light alarm) Gas DetectorPacking list

SKU
NB016196
Detect gas
H2
Range
0~1000ppm
detection Accuracy
<± 5%F.S
resolution
1ppm
Response time
≤60s
Sensors Life
24 months
Sensors principle
electrochemistry
Power Supply
Explosion-proof 10-30V DC Power Supply
Sampling method
diffusion
Operating Mode
Long-term continuous work
Output signal
3-Wire 4-20mA analog output, RS485 output (optional)
structural material
die casting aluminum
transmission distance
≥ 1000 meters
Connectivity
G1/2 male thread explosion-proof hose
Protection level
IP65
Operating temperature
-20~50℃
Environmental humidity
0~90%RH
Low alarm point
20
High alarm point
50ppm
DX30A-H2 (with display + sound and light alarm)
Gas Detector
DINGDING DX30A-H2 Hydrogen Gas Detector with display + sound and light alarm 0-1000ppm Picture

Introduction

The fixed ammonia detection transmitter (probe) adopts a professional imported sensor, which has stable performance, sensitivity and reliability, and good toxicity. It can be divided into display or non-display, explosion-proof or non-explosion-proof, diffusion or pumping. This transmitter is characterized by maximum flexibility, excellent performance and low installation costs. It is used in the place where various toxic gases leak.

peculiarity

  • Professional microprocessor technology, good stability, strong interference ability

  • Three-wire 4-20mA analog output and 1 SPDT relay output

  • RS485 output to save transmission cables (optional)

  • High-low concentration light alarm, and the alarm concentration can be adjusted

  • Non-explosion-proof occasions can be selected high-power sound alarm

  • It adopts high-brightness digital tube or dot matrix Chinese character liquid crystal display

  • Explosion-proof 10-30V DC power supply

  • The response speed is fast and the measurement accuracy is high

Application

  • City gas, petroleum, chemical industry, steel, special industrial plants and other fields.