Germany QNix4200P magnetic platings Thickness Gauge is a split strip iron-based Film Thickness Gauge, used to test the nonmagnetic coating thickness on magnetic metal substrates, QNix4200P range 0-3000um, QNix4200P platings Thickness Gauge adopts wear-resistant ruby probe, long life.
Model:

Qnix QNix4200P Coating Thickness GaugeSPEC

Qnix QNix4200P Coating Thickness GaugeDetails

Qnix QNix4200P Coating Thickness GaugePacking list

SKU
NB016666
Measurement principle
Magnetic Induction
Measurement range
0~3000μm
margin of error
±3%
Resolution
0.1μm|1μm
Minimum measurement surface
25mm
Minimum radius of curvature
Convex 5mm; Concave 25mm
thinnest substrate
0.2mm(F)
probe
Split probe
Probe material
ruby
Calibrated Certificate
Yes.
Calibrated mode
No need to calibrate
Unit display
μm
Interface
USB
Data storage
Temperature -10~60 ℃ (14~ 140 ° F)
Power Supply
2 AA batteries
Standards
DIN EN ISO 2808, ISO 2178, ASTM B 499, ASTM D 7091
Language
German, English
Display screen
LCD screen
Operating temperature
0~50℃
Machine Weight
105g
Machine size
100*60*27mm
QNix4200P
Coating Thickness Gauge
Germany Nix QNix4200P split magnetic platings Thickness Gauge 0-3000um Picture

Introduction

Germany's QNix4200 magnetic coating Thickness Gauge is widely used in the fields of coatings and automotive coatings. It is a standard version of the all-in-one coating Thickness Gauge that uses an iron-based probe and has a measurement range of 0~3000μm. The QNix4200 magnetic coating Thickness Gauge has a minimum measurement diameter of 25mm and has a temperature compensation function.

German QNix4200 magnetic coating Thickness Gauge display diagram

product advantages

1. Simple and fast measurement

2. No calibration required

3. Automatic switch on and off

4. Large range FE: 0-5000um NFE: 0-3000um

5. Dual-purpose probe, high cost performance

6. Hall sensor makes measurement more stable

7. Sound synchronization during measurement

8. Ruby wear-resistant head, long life

9. Backlight LED display for clearer readings

10. Automatically identify the measurement substrate

11. Split probe to meet different measurement environments

plan

German QNix4200 split magnetic coating Thickness Gauge

German NIX QNIX full range of Thickness Gauges

model4200/4200P4500/4500P1200150075008500
matrixFeFe/NFeFeFe/NFeFe, NFe, Fe/NFeFe/NFe
Probe formOne body, two bodiesOne bodyOne body, two bodiesWired/wireless split
Measuring range

0-3000μm​​

0-5000um

Fe:0-3000μm

0-5000um

NFe: 0-3000μm 

0-2000μm0-5000μm

0-2000μm

0-5000μm

(optional)

measurement accuracy0-50μm: ≤±1μm; 50-1000μm: ≤±1.5%; 1000-2000μm: ≤±2%; 2000-5000μm: ≤±3%
Display accuracy0.1μm0-99μm: 0.1μm; 100μm-999um: 1um; above 999um, 0.01mm0.1um/0.01um (optional)
Operating temperature-10 - +60℃
Temperature compensation0-50℃
storage-1500M typeModel 7500MType 8500M
3900 measured values, 999 data sets9999 readings, 100 data sets
Statistics function-Average, maximum, minimum, standard deviation
Over limit alarm-Upper and lower limits
small matrix10mm×10mm
small curvatureConvex and concave radius: 3mm/25mmConvex radius: 5mm, concave radius: 25mm
thin matrixFe: 0.2mm, NFe: 0.05mm
power supply2 AA batteries1 9V alkaline battery
2 AA batteries
weight110g130g150g130g
size110×60×27mm166×64×34mm110×60×24mm124mm×67mm×33mm


FAQ
QQNix4200 Coating thickness gauge with p and without p what is the difference?
A Hello, with p is a split type, without p is an integrated type.
QCoating thickness gauge can be applied to ISO2178?
A OK
QWhat is the average value of the Nix 4200 thickness gauge?
A Hello, the average shown in the measurement is the average of the last three readings, including this measurement.
QExcuse me QNix4200P thickness gauge can continuous measurement?
A Hello, no, Nix's QNix4200 Coating thickness gauge can only be measured once, pick up the instrument after each measurement, leave the measured object more than 10cm, and then perform the next measurement.