TIMEPOWER TP303 Infrared Spectrophotometer

Model:
Certificate

TIMEPOWER TP303 Infrared photometerSPEC

TIMEPOWER TP303 Infrared photometerDetails

TIMEPOWER TP303 Infrared photometerPacking list

SKU
NB017047
Scanning range
3400cm-1~2400cm-1
Wavenumber Repeatability
±1cm-1
Wavenumber Precision
±1cm-1
Spectral resolution
1 cm-1
Absorption linear range
0.0000~1.9999
correlation coefficient
R > 0.999 (infrared non-dispersion method)
Measurement range
0.01~800mg/L
Minimum detection concentration
0.0001mg/L
Maximum detection concentration
80000Mg/L (diluted measurement)
Detection limit 3SD
<0.1mg/L
Baseline drift
1%/4h
Different ratio measurement error
< 5% (mixed hydrocarbons in different proportions simulate actual water samples)
Weight
13kg
Power supply Voltage
220V±10v, 50Hz
Power
40w
CQ1000-ⅰ Extraction Bottle-Extraction Efficiency
>95%
CQ1000-ⅰ type extraction bottle - extraction time
<2min
CQ1000-ⅰ type extraction bottle - extraction Capacity
500ml
CQ1000-ⅰ type extraction bottle - extraction quantity/time
1 sample
CQ1000-ⅰ Extraction Bottle-Weight
6kg
CQ1000-ⅰ type extraction bottle - external size
300×250×650(mm)
CQ1000-ⅰ Extraction Bottle-Power Supply
220V50Hz
CQ1000-ⅰ Extraction Bottle-Power
10W
TP303
Infrared photometer
TIMEPOWER TP303 Infrared Spectrophotometer Picture

Introduction

TP303 infrared photometric oil Tester is a high-precision analytical instrument, in line with HJ637-2012 standard. The instrument is mainly used for the detection of various oil concentration content in environmental water bodies and industrial wastewater by environmental monitoring departments and production departments.

Times Xinwei TP303 infrared photometer

Features

  • LCD display, simple and convenient operation.

  • Good stability. The unique automatic switching mechanism between the sample and the reference cell is used to accurately position, eliminate errors, stabilize the measurement effect, and achieve automatic zeroing. The integrated optical path system is adopted, the optical path design is unique, the signal is strong, and the signal-to-noise ratio is high.

  • True three waves: in line with the national standard HJ637-2012, there is no need to do a standard curve, only a set of correction coefficients.

  • Accurate positioning: The cosecant method is used to accurately locate and scan the wavenumber, so that the wavenumber positioning accuracy is less than one wavenumber. The wavenumber can be freely compensated for positioning.

FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.