GAOPIN NGP5-VOC-A fixed VOC alarm, range: 0-200ppm

GAOPIN fixed VOC alarm, model NGP5-VOC-A, is an online VOC gas concentration alarm instrument, using thermal conductivity detection principle, NGP5-VOC-A fixed VOC alarm with 1.7 inch color screen, with a variety of Alarm modes.
Model:

GaoPin NGP5-VOC-A Fixed VOC alarm instrumentSPEC

GaoPin NGP5-VOC-A Fixed VOC alarm instrumentDetails

GaoPin NGP5-VOC-A Fixed VOC alarm instrumentPacking list

SKU
NB017458
Detect gas
VOC
Application
Petroleum, chemical, pharmaceutical, environmental protection, gas distribution, warehousing, flue gas analysis, air treatment and other occasions that require fixed installation and online detection of gas concentration
range
0~200ppm
Resolution
0.1ppm
Detection principle
thermal conductivity
Display
LCD liquid crystal display
Accuracy
≤±3%(F.S)
Sensors Life
5 years
Linearity
≤±2%
Repeatability
≤±2%
uncertainty
≤±2%
Response time
≤20s(T90)
recovery time
≤ 30 seconds
Signal output
Bus system RS485 (RTU), three (four) wire system 4~ 20mA, optional: 0~20mA, 1~ 5V, 0~5V, 0~10V, wireless transmission, network transmission, SMS alarm
Operating Environment
Temperature: -40 ℃~ + 70 ℃, Humidity: ≤ 10~95% RH, Built-in Filter can be used in high Humidity or high dust environment
Display
On-site 1.7-inch high definition color screen display, optional on-site no display, or optional MIC2000 Controller remote display, control, alarm
Power Supply
12~ 30VDC DC, the standard Power Supply of a single device is 24V, 1A or greater than 1A DC regulated switching Power Supply
Power Supply
24V, 2.1A switching Power Supply can drive 40 toxic Gas Detectors, or 15 combustible, infrared Gas Detectors
Operating Mode
Fixed installation, online detection, diffusion measurement; optional pipeline, flow, pump suction measurement
Installation method
Pipeline type, wall-mounted type. Working pressure of pipeline type is atmospheric pressure +/- 30%, beyond the range needs to be reduced pressure treatment
Alarm mode
Default 1 channel, optional 2 passive touchpoint (dry node) output, three-level alarm, alarm point can be set. On-site sound and light alarm (optional)
Connecting cable
4~ 20mA choose three-core Shielding cable, RS485 choose four-core, when the distance exceeds 1000 meters, the single Wire diameter is ≥ 1.5mm; Shielding is connected to the earth
Protection level
IP65
Explosion-proof type
flameproof type
Explosion-proof sign
Exia II CT6, Certificate No.: CNEx15.1283
Dimensions
210*170*85mm
Weight
1.8Kg
Standard Accessories
Manual, Certificate of Conformity, Warranty Card, Encasement Box
Option
Integrated acousto-optic alarm, split acousto-optic alarm, 24V DC regulated Power Supply, accessories connected to computer monitoring: free host computer software, RS485/RS232 converter, laptop without RS232 interface also requires USB/RS232 conversion cable, if you want network transmission, TCP/IP converter is required.
wireless transmission
Optional function, you can wirelessly transmit data to mobile phones, remote monitoring centers, monitoring computers and other monitoring equipment, and use the host computer to perform Data analysis, storage, printing and other functions on the computer
preprocessing system
Optional: room temperature and high humidity pretreatment system, high temperature and high Humidity pretreatment system, high temperature, high humidity and high dust pretreatment system
Installation Accessories
Optional: wall mounting bracket, installation buckle fixed on the pipe (four-point, six-point pipe), pipe mounting stainless steel thread welding seat or flange (need to indicate the pipe or flange size, such as DN50, DN15...), rain cover, 24VDC or 220AC sampling pump (sampling distance 10 meters), vacuum pump (sampling distance greater than 40 meters), 24V switching Power Supply, pressure reducing valve, Flow rate meter
NGP5-VOC-A
Fixed VOC alarm instrument
GAOPIN NGP5-VOC-A fixed VOC alarm, range: 0-200ppm Picture

Overview

Gaopin Technology NGP5-VOC-A fixed VOC alarm is an online VOC Gas Detector, which is used for 24-hour continuous online monitoring of gas concentration on site, 1.7-inch high-definition color screen display on-site concentration, on-site sound and light alarm (optional), remote signal transmission. The gas sensor of the international good brand is adopted, and the detection principle is the principle of thermal conductivity. NGP5 series Gas Detector is suitable for detecting the concentration of gas in pipelines or confined spaces and atmospheric environments, gas leakage and high concentration of nitrogen or oxygen in various background gases. More than 500 types of tests have been tested. The rugged explosion-proof shell is suitable for all kinds of dangerous places and harsh industrial environments, and is widely used in petroleum, chemical, metallurgy, refining, gas transmission and distribution, biochemical and other industries.

Product dimensions

Dimensional drawing of Go&P NGP5-VOC-A fixed VOC alarm

Features

● Free switching of units

● Diversified communication methods

Real-time monitoring can be carried out through wired or wireless remote transmission and network transmission, three-wire 4~20mA standard signal and standard bus RS485 (modbus-RTU) output at the same time, optional frequency output 200-1000Hz, Hart protocol signal, 1~5V output, two-wire system 4~20mA, SMS alarm, wireless transmission (2~5 km or unlimited distance), compatible with secondary instruments, data acquisition module, PLC, DCS system, can drive related equipment.

● Infrared remote control

The infrared remote control is equipped as standard, and the function keys of the infrared remote control can be operated with one button, which can realize the operation without opening the cover in dangerous situations, such as: modify the alarm point, concentration calibration, zero point calibration, silence, factory recovery and other functions.

● Rich man-machine interface

1.7-inch high-definition color screen, showing real-time concentration and alarm status.

● High Temperature Gas Detection (Optional)

The optional high-temperature and high-humidity pretreatment system can detect high-temperature flue gas.

● Data recovery function, in case of misoperation, you can choose to partially or fully recover.

● You can set whether to display the maximum and minimum values.

● A variety of alarm methods, multi-directional three-dimensional indication of alarm status when alarming.

Including: 2 sets of relay switching output, sound and light alarm (optional), display visual alarm. The types of alarms include: concentration alarm, fault alarm.

● Multiple alarm mode settings: low alarm, high alarm, interval alarm, weighted average alarm.

●Misoperation identification function: Misoperation of concentration calibration is automatically identified and prevented to avoid defects caused by human factors.

● Zero point automatic tracking, long-term use is not affected by zero point drift.

● Multi-level calibration of the target point to ensure the linearity and accuracy of the measurement.

● Chinese or English interface can be selected.

● Operating temperature: -40~+70°C, support temperature compensation.

● Logging.

Record calibration logs, maintenance logs, fault records, fault resolution countermeasures, sensor life expiration reminders, and next concentration calibration time reminders.

● Intrinsically safe circuit design, explosion-proof, with secondary lightning protection and anti-static capabilities. It meets the national standard and resists the impact of high-intensity pulse surge current. It has the function of anti-reverse connection. EMI AND C EMC compliant.

Pictures

Gaopin Technology NGP5-VOC-A fixed VOC alarm display diagram