China

EYESKY ES10B11-N2 Fixed Nitrogen Detector, Range 0-100% Vol

EYESKY fixed nitrogen Detector, model ES10B11-N2, detection range is 0-100% Vol, is a wall-mounted online nitrogen Detector, ES10B11-N2 fixed nitrogen Detector with sound and light alarm function, with LCD screen.
Model:

EYESKY ES10B11-N2 Fixed nitrogen Detector SPEC

EYESKY ES10B11-N2 Fixed nitrogen Detector Details

EYESKY ES10B11-N2 Fixed nitrogen Detector Packing list

SKU
NB017460
Detect gas
N2
Sensors principle
electrochemistry
Sampling method
diffusion
N2 range
0~100% Vol (optional, unlisted ranges can be customized)
N2- resolution
0.01%VOL
detection Accuracy
±3%F.S.
Operation mode
Infrared remote control for remote and close operation, easy to set up
Repeatability
≤±1%
Zero drift
≤ +/- 1% (F. S/year)
Response time
T90≤20s
recovery time
≤20s
Explosion-proof sign
Exd Ⅱ CT6
Protection level
IP66
Output signal
Users can according to the actual site environment requirements, up to 2000 meters (single core 1mm2 Shielding cable) three-wire system 4-20mA current signal output, can be connected to the alarm Controller, PLC, DCS and other Control system (standard configuration)
main material
Shell: ADC12 aluminum alloy, strong, wear-resistant and corrosion-resistant (optional 316 stainless steel shell) Air chamber: high-strength wear-resistant and corrosion-resistant Aluminum profile, durable (optional 316 stainless steel air chamber)
Installation method
Wall-mounted, pipeline type
Operating temperature
-30~60℃
Environmental humidity
0~95% RH non-condensing
Environmental humidity
10%~95%RH
Power Supply
24VDC (Normal Operating Voltage range 12~ 30VDC)
power consumption
1.5W
Operating Pressure
≤200Kpa
Dimension
180*140*92mm
Weight
About 1.6Kg
execution standard
GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010
ES10B11-N2
Fixed nitrogen Detector
EYESKY ES10B11-N2 Fixed Nitrogen Detector, Range 0-100% Vol Picture

Introduction

Visionless ES10B11-N2 fixed nitrogen Detector is a new one created by Visionless Technology on the basis of ES10AGas Detector, using original imported sensors and new ones32-bit low-power processor; Dashboard display boundarysurface, the value and the progress bar are displayed at the same time, which is beautiful and generous; Circuit adoption4 layers of wiring, against weak signals and anti-dryingDisturbance is stronger; Independent high-precision imported 16-bit AD chip and signal processing algorithm to measure data accuracyHigher and more stable;4~20mA, RS485, 200~1000Hz output signals can be selected, easy to accessAlarm controllers,PLC, DCS and other control systems; Explosion-proof structures are designed to be used in a variety of hazardous industriesLocation; The products are widely used in metallurgy, petroleum and petrochemical, municipal, chemical and other industries.

Introduction to the Visionless ES10B11-N2 Fixed Nitrogen Detector

Structural diagram of the ES10B11-N2 fixed nitrogen Detector without vision

Architectural diagram of the display screen of the ES10B11-N2 fixed nitrogen Detector without vision

Appearance of the Visionless ES10B11-N2 Fixed Nitrogen Detector

Visionless ES10B11-N2 Fixed Nitrogen Detector Alarm Indication

Visionless ES10B11-N2 fixed nitrogen Detector adopts imported high-precision sensor

Visionless ES10B11-N2 Fixed Nitrogen Detector Air Intake

Visionless ES10B11-N2 Fixed Nitrogen Detector with a variety of signal outputs

Visionless ES10B11-N2 fixed nitrogen Detector Operating Environment

Features

◆ Imported high-performance sensor, high measurement accuracy, good repeatability and long service life;

◆ Independent 16-bit AD chip, 4-layer circuit board design, stronger ability to weak signal and anti-interference;

◆ The dashboard display interface is designed, the reading is beautiful and generous, and the humanized detail design is reflected;

◆ White, orange and red backlight design, normal and alarm status indication, clear at a glance;

◆ mg/m3, ppm, VOL, LEL can be selected;

◆ Embedded 32-bit ultra-low power processor, with independent signal processing algorithm, fast response speed and stability;

◆ Automatic protection function against high-concentration gas impact, with factory reset to prevent misoperation;

◆ The instrument is equipped with infrared remote control, which can be operated by remote control, without opening the cover, which is simple and convenient;

◆ Three-wire 4~20mA, RS485, 200~1000HZ signal output optional, relay output, data recovery, data storage and other functions;

◆ Two cable inlets, convenient for on-site installation;

◆ Independent air chamber structure, easy sensor replacement, no need for on-site calibration;

◆ Very good mechanical design, the air chamber is made of high-strength aluminum profile of military quality, wear-resistant and corrosion-resistant, suitable for complex and harsh industrial environments, reasonable and scientific air chamber design, to ensure the accuracy of real-time monitoring of the sensor;

◆ The explosion-proof grade is Exd II CT6, which is certified by the National Explosion-proof Electrical Inspection Center.

FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.