United Kingdom

ION SCIENCE Tiger PhoCheck PCT-CNG Military Gas Detector ppb~ 20000ppm

ION SCIENCE Tiger PCT-CNG Gas Detector adopts grid electrode technology, built-in WMD gas correction coefficient, PCT-CNG Gas Detector can detect hydrogen arsenide, tabun poison gas, micro-Krasse gas, mustard gas light gas.
Model:
Certificate

Ion Science PCT-CNG Gas DetectorSPEC

Ion Science PCT-CNG Gas DetectorDetails

Ion Science PCT-CNG Gas DetectorPacking list

SKU
NB017527
Range
1Pb~ 20000ppm or mg/m3
resolution
1ppb
detection Accuracy
±5%
Response time
<2sCT90)
security certification
ATEX 112G Ex ia IIC T4 (- 15℃≤Ta≤+60℃), IECEx and CUL
Power Supply
Up to 24 hours, 6.5 hours of charging
PID lamp
10.6eV
Data storage
>120,000
Interface
USB 1.1
Alarm mode
LEDs, sound and vibration, sound 95dB
temperature
Operating temperature: -20~60'C, -4~ 140 "F
Environmental humidity
0~99% C non-condensing)
Weight
0.72kg
Dimension
420*320*97mm
Protection level
IP65
Flow rate of pump
220ml/min
gas
Organic volatile gases, WMD chemical warfare agent gases
PCT-CNG
Gas Detector
ION SCIENCE Tiger PhoCheck PCT-CNG Military Gas Detector ppb~ 20000ppm Picture

Introduction

● Grid electrode technology

● Dynamic detection range for specific volatile organic gases (VOC's).1ppb-20, 000ppm

● Built-in WMD chemical warfare agent gas correction factor

● Ultra-large range detection, 3-point calibration, to ensure accurate readings of high-low concentrations

● It has health and safety mode (STEL &TWA) and data storage function

● Easily replaceable mini PID Detector, electrode stack and lamp

● Easier to use and more intuitive, connecting to a PC requires no complicated installation procedures

● The battery lasts up to 24 hours and can be replaced in hazardous areas

● ATEX, IECEX and CUL certified

● Sturdy protective design, detachable rubber jacket

● Loud 95dBA alarm sound, bright LED flashing lights and vibration alarm

● The smallest and lightest PID monitor for personal protection in effect

● Detection range: 1ppb-5000ppm

● Simple one-button operation, LCD large screen clear

● Readings are displayed

● Clear audible, visual and vibration alarms

● ATEX, IECEX


WMD chemical warfare agent gas

Arsine hydrogen arsenideTabun gasVX Vickers gas
Mustard Gas(HD) mustard gasGF methofaronate cyclohexyl esterDMMP dimethyl phosphate
Sain sarin gasSoman Suman gasMethyl salicylate and so on
FAQ
QIs this the Gas detector mentioned in GB15322.1?
A OK
QWhat is the alarm prompt design of Phocheck Tiger Military Gas detector?
A Hello, PCT-CNG Gas detector has sound and light alarm prompt, including 95dBA alarm sound, LED flashing light and vibration alarm.
QWhat are the calibrated maintenance kits of Tiger PCT-CNG Gas detector?
A Hello, there are 5 Spare Filters, Carbon Filter, Mini PID Removal Tool, Small Dose Anodized Aluminum Cleaner and PID Lamp Cleaning Cotton.
QWhat is the detection gas concentration range of Ion Science PCT-CNG?
A Hello, the range is 1ppb~ 20000ppm, and the accuracy is ± 5%.
Knowledge
Standard