China

PUSHEN Zahn 2 #Zahn Cup Zahn Cup

SE
Viscosity range 20-250cSt; nozzle diameter 2.7mm; portable; stainless steel; meets ASTM D4212 standard.
Model:
Certificate

Pushen Zahn-2# Zahn CupSPEC

Pushen Zahn-2# Zahn CupDetails

Pushen Zahn-2# Zahn CupPacking list

SKU
NB018122
Viscosity range
20~250cSt
outflow time
20~80s
Flow hole diameter
2.7mm
Cup body material
stainless steel
Filter material
stainless steel
Handle material
stainless steel
Applicable standard
ASTM D4212
Environment temperature
25℃±0.2℃
Certificate
without
Zahn-2#
Zahn Cup
Viscosity range 20-250cSt; nozzle diameter 2.7mm; portable; stainless steel; meets ASTM D4212 standard.
PUSHEN Zahn 2 #Zahn Cup Zahn Cup Picture

Zahn Cup

It can be used anywhere in factories, workshops and laboratories to quickly check the viscosity of fluids.

Each cup has a 30 cm long ring handle that can be held by hand to submerge the cup in the liquid.

There is a ring in the center of the handle to keep the cup vertical during the test.

Pushhen Zahn-2# Zahn Cup Details Figure 1

Pushhen Zahn-2# Details of Zahn Cup 2

Pushen Zahn-2# Zahn Cup Details Figure 3

Standards

ASTM D 4212

Comparison of parameters of PS ZAHN Cup series

modelcup numberoutflow apertureMeasuring rangeoutflow time
PS 1024/1number 125-6035-80
PS 1024/2number 22.720-25020-80
PS 1024/3number 33.8100-80020-80
PS 1024/4No 44.3200-120020-80
PS 1024/5Number 55.3400-180020-80
Unit: mm, cSt, s
Other parameters
StandardsASTM D 4212
materialStainless steel
FAQ
QZahn Zahn Cup in the cosmetics industry?
A In the cosmetics industry, the Zahn Zahn Cup is commonly used for the measurement of the viscosity of cosmetic products such as emulsions and serums to ensure that their applicability and feel meet the requirements, and can also be used for liquid viscosity control during the preparation process.
QHow to handle high temperature liquids when using Zahn Zahn Cup?
A For high-temperature liquids, the liquid can be cooled to the test temperature by placing it in a constant-temperature water bath, and then tested to ensure the accuracy of the test results.
QWhat is the use of the rings on the cup of the Zahn Zahn Cup?
A There is a ring in the center of the handle to keep the cup vertical during testing. Each cup has a 30cm-long ring handle that allows the cup to be immersed in liquid by holding it with your hand.
QIs there any correlation between outflow time and viscosity range?
A Yes, the outflow time is positively correlated with the viscosity of the liquid being tested. In general, liquids with higher viscosity have a longer outflow time, while liquids with lower viscosity have a shorter outflow time.
QAre the Pushin Zahn cups made of stainless steel?
A Hello, yes. Compliant with ASTM D4212 standard.
QWhat is the viscosity range of this viscosity cup?
A Hello, the domestic (CN) Zahn No. 2 viscosity cup is suitable for the measurement of fluid viscosity in the range of 20-250cSt, and the flow is actually between 20-80s.
QCan this PUSHEN Zahn Cup correspond to ASTMD1084?
A Yes, please refer to the NBchao standards page for specific standards.
QHow many mm is the outflow diameter of Puxen ZAHN Zain Cup No. 2?
A Hello, the outflow diameter of No. 2 Zain Cup is 2.7mm.
Knowledge
Standard