PUSHEN MFFT minimum film forming temperature (MFFT) Tester
SE
Resin emulsion detection layer heating drying conditions to form a continuous uniform without the lowest temperature of the crazing film, layer plate Operating temperature range -7~ 70 ℃, temperature measurement point 13 points, layer plate size 300 * 200mm, Spreader the number of samples 6.
Pushen MFFT Minimum film forming temperature (MFFT) TesterSPEC
Pushen MFFT Minimum film forming temperature (MFFT) TesterDetails
Pushen MFFT Minimum film forming temperature (MFFT) TesterPacking list
SKU
NB018130
input Voltage
220V
Layer operation temperature range
-7~70℃
Temperature measurement point
13 point
Layer board size
300*200mm
Number of Applications
Article 6
Test strip size
240*22mm
Overall Dimensions
520*520*370mm
Shipment Weight
40KG
MFFT
Minimum film forming temperature (MFFT) Tester
Resin emulsion detection layer heating drying conditions to form a continuous uniform without the lowest temperature of the crazing film, layer plate Operating temperature range -7~ 70 ℃, temperature measurement point 13 points, layer plate size 300 * 200mm, Spreader the number of samples 6.
Minimum film forming temperature Tester
It refers to the minimum temperature at which the resin emulsion forms a continuous and uniform film without cracks under gradient heating and drying conditions.
Its main structure is a metal gradient plate, and the two ends of the gradient plate are respectively provided with a cooling source and a heating source. Through the principle of metal heat conduction, different temperature gradients are generated on the metal plate. Coat a wet film of emulsion or compound dispersion with uniform thickness on the temperature gradient plate, dry the sample with dry air flow, and the sample is affected by the temperature on the gradient plate to form a film based on moisture.
Due to the different temperature on the gradient plate, the position of the film formation of the sample is also different. Find the junction point where the continuous transparent film and the white opaque (unpolymerized) are formed . The temperature corresponding to this point on the gradient plate can be obtained from the screen display. The temperature is is the minimum film-forming temperature of the sample.
[Note]Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
QMMFT meter each layer board size?
A
300*200mm。
QI want to do a test about the GB/T9267 standard. Is this minimum film forming temperature (MFFT) tester okay?