Back

Ion Science FAL-3000P Fixed VOC online monitor Specifications

Search
UK ION SCIENCE FALCO FAL-3000P Fixed VOC Online Monitor, Pump Suction

Brand:Ion Science

Model:FAL-3000P

Name:Fixed VOC online monitor

DetailsContact
Specifications
Sampling method Pump suction
Detection principle PID
range 3000ppm
resolution 1ppm
Response time ≤30s(T90)
user interface OLED display: high contrast ratio, black background and white text 128x64px; Screen size: 35x17.5mm; 5 magnetic switches with LED confirmation lights (up, down, left, right, confirmation), with exciter
status indicator Bright and visible status indicators: red, orange, and green
certification Ex II 2G Ex d ib IIC T4 Gb。ISO9001:2008
Operating temperature -20℃~60℃
Operating humidity 0~100% Relative Humidity and Humidity
Mechanical interface 2 cable access points with 3/4 "NPT threads (left and right); 2 3/4" NPT threads for M20 stainless steel (configured)
Dimension 290*190*125mm
Installation point 2 M8
Input Power Operating Voltage: 12~ 40Vdc; Maximum Power: 7W
output 4~ 20mA (active and passive); RS485 supports Modbus protocol; configurable relays and 2 SPST switches
Packing list
After-sales instructions

None

[Note] For after-sales services outside the Chinese mainland, if the instrument requires repair, the shipping and possible associated taxes shall be borne by the sender. Generation address of the manual: http://en.nbchao.com/p/18423/Specification.html , which is only used by users who purchase commodities from the NBCHAO.