China

PUSHEN ISO-8 ISO Flow Cup 8mm/aluminum single cup

Outflow time 30~100s, flow hole diameter 8mm, cup height 86mm, cup width 56mm, Total height 86mm, cup body material anodic oxidation aluminum, filter material stainless steel, Applicable standards ASTM D5125, ISO 2431.
Model:
Certificate

Pushen PS 1020/8 ISO Flow CupSPEC

Pushen PS 1020/8 ISO Flow CupDetails

Pushen PS 1020/8 ISO Flow CupPacking list

SKU
NB019425
outflow time
30~100s
flow hole diameter
8mm
Cup height
86mm
Cup width
56mm
Total height
86mm
Cup body material
Aluminum anodic oxidation
Filter material
stainless steel
Applicable standard
ASTM D5125、ISO 2431
PS 1020/8
ISO Flow Cup
Outflow time 30~100s, flow hole diameter 8mm, cup height 86mm, cup width 56mm, Total height 86mm, cup body material anodic oxidation aluminum, filter material stainless steel, Applicable standards ASTM D5125, ISO 2431.
PUSHEN ISO-8 ISO Flow Cup 8mm/aluminum single cup Picture

  The ISO outFlow Cup is designed and manufactured in accordance with the relevant provisions of the international standard ISO2431-1993 for the determination of the outflow time and the national standard GB/T6753.4-98 for the determination of the outflow time of paints - ISO outFlow Cup method. This outFlow Cup is used to test the outflow time of Newtonian or near-Newtonian liquids.

Main technical parameters:


ModelOutflow pore sizeMeasuring rangeRun out of timeThe width of the cupCup heightweightMeets standards
Number 33mm7-42 cSt30-100s56mm86mm268gASTM D 5125,ISO 2431
Number 44mm34-135 cSt25-100s
Number 55mm91-326 cSt25-100s
Number 66mm188-684 cSt25-100s
Number 88mm--Customized
Note: Brackets can be purchased separately



The actual picture of the ISO outFlow Cup

Exterior view of the PSON ISO Cup

Diagram of different models of Pushen ISO Cup

Diagram of the Pursson ISO Cup, Ford Cup, and Din Cup

Equipment and utensils

1. Stopwatch: Accuracy 0.1 (bring your own)

2. OutFlow Cup holder (optional)

How to use:

1. Before or after measuring, wipe the inner wall with fine gauze dipped in the solution repeatedly, twist it into a rope shape with soft paper, and repeatedly pull it clean in the outflow hole.

2. Place the outFlow Cup onto the stand and adjust the level of the stand.

3. Prepare a stopwatch with an accuracy of 0.1 seconds while holding down the outflow hole with your hand.

4. Slowly pour the measured liquid at a controlled temperature (according to the user's requirements) into the outFlow Cup to avoid bubbles, and scrape flat with a scraper or glass when the liquid exceeds the mouth of the cup.

5. Start the stopwatch and quickly release the finger holding the outflow hole at the same time, and press the stopwatch at the moment when the outflow liquid is interrupted to record the outflow time.

Calculation method:

The measured outflow time is calculated as the kinematic viscosity mm /s according to the following formula

Cup numberISO-3
ISO-4ISO-5ISO-6
formulaV=0.443t-200/tV=1.37t-200/tV=3.28t-220/tV=6.90t-570/t

where: v=mm² /s

      t = outflow time

      Centistock = K value × outflow time - (C÷ outflow time)

      centipoise = centistock × specific gravity

Note: In order to obtain more accurate data, the outflow time can be measured multiple times and the average value can be calculated.


FAQ
QIs this ISO flow cup compliant with ISO2431 standard?
A The ISO flow cup is suitable for ISO2431, please consult customer service for detailed application definition
Standard