China

BOXUN YXQ-50G Vertical pressure steam Autoclave 50L 2 baskets with drying

50L volume, automatic control type, with drying, microcomputer control, with domestic (CN) circulation exhaust steam type, with 3 liters gas collection cylinder, automatic water entry, heating sterilized, steam drainage.
Model:

Boxun YXQ-50G Vertical Pressure Steam AutoclaveSPEC

Boxun YXQ-50G Vertical Pressure Steam AutoclaveDetails

Boxun YXQ-50G Vertical Pressure Steam AutoclavePacking list

SKU
NB020142
Shell material
SUS304
Cylinder material
SUS304
Basket material
SUS304
Volume
50L
Power
3.2Kw
Drying Power
0.8kW
Power supply Voltage
220V±10% 50Hz±2%
Operating temperature
135℃
Operating temperature
138℃
Working pressure
0.22MPa
Working pressure
0.25MPa
Timer Range
4~120min
Drying Timer
30~240min
Sterilizing chamber size
Ф400*640mm
Basket size
Ф360×240mm
number of baskets carried
2
Dimension
485*605*1120mm
YXQ-50G
Vertical Pressure Steam Autoclave
50L volume, automatic control type, with drying, microcomputer control, with domestic (CN) circulation exhaust steam type, with 3 liters gas collection cylinder, automatic water entry, heating sterilized, steam drainage.
BOXUN YXQ-50G Vertical pressure steam Autoclave 50L 2 baskets with drying Picture

Scope of application

Sterilizer series products are the use of pressure saturated steam for rapid and reliable disinfection and sterilization of products, suitable for scientific research, agriculture and other units, dressings, glassware, solution culture media, etc.

Features

Self-controlled, with drying type

Handwheel type quick-opening safety interlocking device structure

The shell, cylinder and basket are all made of SUS304 material, which is acid-resistant, alkali-resistant and corrosion-resistant

Microcomputer intelligent automatic control

Pressure safety interlock device, over-temperature automatic protection device

Self-rising seals for automatic cold air discharge

Overpressure self-discharge, low water level alarm, water cut-off automatic control, extreme over-temperature protection device

Internal circulation exhaust type with 3 liter gas collector cylinder

Automatic water intake, heating sterilization, steam drainage, drying

After the work is over, the buzzer reminds and automatically stops

Sample test holes are provided as standard

Sterilization and drying work process

A: Sterilization and sterilization are completed;

b: Sterilization and steam release after sterilization;

c: Sterilization, venting, drainage, drying.

Matching:printer

Melt-keep function (melting temperature 60~98°C, time range 0~999 minutes; Heat preservation temperature 40~60°C, time range 0~999 minutes)

The medical type is equipped with a pressure protection device


FAQ
QI would like to ask if the YXQ-50g sterilizing pot is fully automatic? Do you add water automatically or manually?
Standard