Multiparameter water quality measurement, designed for field measurements in harsh environments. The instrument supports simultaneous measurement of pH, ORP, dissolved oxygen, atmospheric pressure and temperature five key water quality indicators, with IP67 waterproof and anti-skid body and IP68 waterproof electrode, ensuring Reliability in complex environments such as pipelines or deep wells.
$1743.00/set
PromotionLoading...
Coupon
Model:

HANNA HI98196 Multiparameter DetectorSPEC

HANNA HI98196 Multiparameter DetectorDetails

HANNA HI98196 Multiparameter DetectorPacking list

SKU
NB020322
PH range
0.00~14.00  pH/±600.0 mV
PH Measurement Accuracy
±0.02 pH/±0.5mV
PH calibrated mode
Up to three-point automatic calibrate recognition and one custom calibrate, built-in five standard calibrate points 4.01, 6.86, 7.01, 9.18, 10.01 pH
ORP Measurement range
±2000.0mV
ORP resolution
0.1 mV
Measurement Accuracy of ORP
±1.0 mV
ORP calibrated mode
Single point custom calibrated (relative mV)
Measurement range of dissolved oxygen
0.0~500.0%; 0.00~50.00 ppm
Resolution of dissolved oxygen
0.1%;0.01 ppm
Measurement Accuracy of dissolved oxygen
0.0-300%: reading +/- 1.5% or +/- 1.0%, whichever is the largest; 300.0-500%: reading +/- 3%; 0.00-30: reading +/- 1.5% or +/- 0.10ppm whichever is the largest; 30.00-50
Dissolved oxygen calibrating mode
Single or double point calibrated Automatic calibration, zero or air automatic 100% calibrated
Measurement range of atmospheric pressure
450.0~850.0 mm Hg;17.72~33.46 in  Hg;600.0~1133.2 mbar;8.702~16.436 psi; 0.5921 to  1.1184atm;60.00~113.32 kPa
atmospheric pressure resolution
0.1mm Hg;0.01 in  Hg;0.1mbar;0.001 psi;0.0001 am;0.01kPa
Measurement Accuracy of atmospheric pressure
±3 mm Hg @±15℃
Atmospheric pressure calibrated mode
Single point user calibrated
Measurement range
-5.00~55.00℃;23.00~131.00℉;268.15 to 328.15K
temperature resolution
0.01℃;0.01℉;0.01K
Measurement Accuracy
±0.15℃;±0.27℉;±0.15K
Temperature calibrated mode
Single point user calibrated
Temperature temperature compensation
Automatic temperature compensation, -5.00~55.00 ℃, 23.00~131.00 ° F
Temperature Data storage
45000 measurement Data storage, (continuous automatic storage or manual storage)
Temperature recording interval
Can be set from 1 second to 3 hours
Temperature Interface
USB Interface (HI9 2000-15 data management software recommended)
Operating Environment
0~50℃(32~122 ℉);RH 100% IP67
Battery operated
1.5V AA battery * 4, about 360 hours of continuous use
Weight/Size
185x93x35.2 mm/400g
HI98196
Multiparameter Detector
Multiparameter water quality measurement, designed for field measurements in harsh environments. The instrument supports simultaneous measurement of pH, ORP, dissolved oxygen, atmospheric pressure and temperature five key water quality indicators, with IP67 waterproof and anti-skid body and IP68 waterproof electrode, ensuring Reliability in complex environments such as pipelines or deep wells.
HANNA HI98196 Water Quality Analyzer PH/ORP/dissolved oxygen/atmospheric pressure/temperature Picture

HI98196 New appearance design, large-screen LCD display, backlight, on-screen operation step prompts, a variety of optional languages, while meeting 7 important indicators of water quality analysis, IP67 excellent waterproof design, easy and fast electrode replacement, for field field measurement. HI98196 meet the needs of 45,000 data continuous storage or manual storage. Customize the storage interval (1 second to 3 hours). Cooperate with HI920015 USB cable and data processing software to transfer data with PC. The GLP management function records the calibration information in detail. Easily press the HELP button to enter the help menu to get on-screen help information and an introduction to the functions of each button.

peculiarity

  • The new ergonomic design, large background light, chart display function, good cost performance

  • The main body is IP67 waterproof and anti-slip design, and the electrode is IP68 waterproof standard, which can meet the measurement of harsh environments such as pipelines or deep wells

  • Multi-parameter integrated electrode design, intelligent electrode holder built-in microprocessor and temperature sensor, can be installed pH (ORP) and EC electrodes at the same time

  • Electrode position is color-coded for easy installation and automatic identification

  • The important water quality indicators of 7 items are quickly measured at the same time, and the full-screen display is clear at a glance

  • Unique quick calibration function, automatic error diagnosis function, automatic recognition of measuring range, easy replacement of measurements

  • Powerful GLP management, large-capacity 45,000 data storage functions, USB data interface, professional data analysis and management software

  • Good anti-electromagnetic signal interference ensures measurement reliability, accuracy, and a wide range of applications


FAQ
QIs the price listed on the website the final cost for overseas purchases?
ANo, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
QWhat is the specific process for purchasing the product?
AFirst, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
QWhat should I do if the instrument I purchase needs repair?
AAfter-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
Standard