China

JINGTIAN RVDV-1H High temperature Rotational Viscometer 10 million mPa·s 250 ℃

SE
JINGTIAN RVDV-1H high temperature Rotational Viscometer adopts embedded integral heating, with blue LCD, RVDV-1H high temperature Rotational Viscometer Measurement range is 100~10000000mPa·s, reproduction accuracy is +/- 0.5%.
Model:
Certificate

JingTian RVDV-1H Digital Rotational ViscometerSPEC

JingTian RVDV-1H Digital Rotational ViscometerDetails

JingTian RVDV-1H Digital Rotational ViscometerPacking list

SKU
NB020612
Display mode
digital
Measurement range
100~10000000mPa·s
Rotor specification
21#、 27#、28#、29#
Reproducibility
±0.5%F.S
Measurement Accuracy
±1%F.S
Power
220V 50Hz
Rotor speed
0.1~99.9rpm
Display information
Viscometer: Viscosity, Rotation speed, Temperature, Percentimeter torque, Rotor number and the maximum viscosity value of the selected rotor at the current Rotation speed. Temperature Controller: Set temperature and actual Measuring temperature display.
Capacity
10~20mL
Temperature range
RT+10~250℃
Temperature Accuracy
±0.1℃
Rotation speed Control mode
Continuously variable speed
RVDV-1H
Digital Rotational Viscometer
JINGTIAN RVDV-1H High temperature Rotational Viscometer 10 million mPa·s 250 ℃ Picture

Introduction

It mainly measures substances that are solid at room temperature and become liquid after heating at high temperature, such as asphalt, hot melt adhesive, polyethylene wax, etc.

It can be used as a stand-alone machine, and the measurement data can be directly displayed on the LCD without secondary calculations; it can also be equipped with "data collection analysis and drawing software" to realize data collection and data analysis, and monitor the viscosity-temperature curve throughout the process.

Using high-resolution stepping motor, the speed is accurate and stable.

LCD liquid crystal with blue backlight function, directly display viscosity, speed, percent torque, rotor number, and the maximum viscosity value and temperature value that can be measured at the current speed of the selected rotor. DV-2 series can also display shear rate and shear stress. The viscosity value shows a continuous change, and there will be an alarm sound when it exceeds the measurement range. 

The measurement performance of the instrument has reached the level of foreign products of the same type through computer correction. 

The high-temperature furnace adopts built-in overall heating, which is evenly heated and has small thermal inertia.

Instrument structure

DVH high temperature viscometer structure diagram


DV-H series selection

modelLVDV-1HRVDV-1HHBDV-1HLVDV-2HRVDV-2HHBDV-2H
Measuring range10~1M100~10M800~80M5~1M50~10M400~80M
(mPa·s)
spinning speed0.1~99.9 stepless speed change0.1~200 stepless speed change
(rev/min)
Rotor configurationNo. 21, No. 27, No. 28, No. 29 rotors each 1 piece
measurement accuracy±1% (FS) Newtonian fluid
Reproducibility±0.5% (FS) Newtonian fluid
Sample volume (mL)10~20
Temperature control range (℃)Room temperature +10~250
Temperature control accuracy (℃)±0.1
power supply220V 50Hz


FAQ
Q20-1 million mps The sample temperature is 80-150 degrees Celsius, right? How many samples do you need for this test? Organic Glass pmma
A Generally, the melting point of PMMA is about 160 ° C. If you want to measure this material by yourself, it is more troublesome to measure it by Viscometer. You need to measure the thermostatic temperature all the time. RVDV-1H is recommended.
QViscosity of epoxy resin Is there a solid epoxy resin viscometer? Can it be measured for solids?
A Solids are measured after heating dissolved Use SNB-RH, RVDV-1H, RVDV-2H after solvent dissolving at room temperature or heating to more than 100 degrees for measurement
QNeed to test the viscosity of epoxy resin, including thermostatic controller, this one can be tested, I want to know how long the temperature and rotor display viscosity value can be displayed on the machine
A Room temperature, direct measurement is enough. If you need to control the temperature of your epoxy resin, it is recommended to choose NDJ-8S or LVDV-1 with LC-1008 low temperature Thermostatic bath, the viscosity is stable and the result is obtained. The whole China 5-8 seconds
QIf it is 200 ° C in the furnace, what is the temperature outside the furnace?
A We do a better job of heat insulation, and the temperature outside the furnace is controlled within about 45 ° C
QThe measurement of plastic particles requires high temperature heating and stirring, and the temperature should reach about 280. Can it be tested?
A 280 degrees can't be measured if it softens, and can be tested if it dissolves. This one can reach 300 degrees.
QHow is the temperature control of the high temperature Viscometer heating device?
A The heating device is specially used for accurate measurement of the viscosity of hot-melt adhesives, paraffin, asphalt, drugs, high polymers and other high temperature liquids. The sample temperature can be controlled to room temperature + 5 ℃ - + 250 ℃. The temperature fluctuation of the heating device is precisely controlled +/- 0.1 ℃. The sample dosage is small 5-20ml, and it can be equipped with a disposable sample cartridge. It can be equipped with a standard SC4 rotor, which is easy to operate and use.
QHow to clean this?
A Like this kind of high-temperature Viscometer cleaning, generally take it down for cleaning under high temperature conditions. Don't wait for the temperature to drop, and then take it directly for cleaning, because it is not sticky under high temperature conditions. It is very annoying to wait until the temperature drops before cleaning. When the temperature drops, it will be more sticky. Some customers will soak it in solvent again.
QMeasure organic matter, oil, everything, is there a Viscometer with a wider viscosity range and heating function to 300 degrees?
A This one is ok.
QIs there a suitable Viscometer for measuring the viscosity of hot-melt adhesive particles?
A Hot-melt adhesive RVDV-1H, SNB-RH, RVDV-2H are all available.
QWe make hot-melt adhesives, what Viscometer recommend?
A Make hot-melt adhesive, RVDV-1H\ RVDV-2H\ SNB-RH can be used.