China

Qiwei PXS-HCO3 Bicarbonate Ion meter

SE
Qiwei PXS-HCO3 bicarbonate Ion meter pHCO3 value (2.00~4.40) pHCO3, HCO3 concentration value 2mg/L~ 0.6g/L, mV value (-1800~1800) mV, used for measurement of bicarbonate ion content in aqueous solution.
$368.00/set
PromotionLoading...
Coupon
Model:
Certificate

QiWei PXS-HCO3 Bicarbonate Ion meterSPEC

QiWei PXS-HCO3 Bicarbonate Ion meterDetails

QiWei PXS-HCO3 Bicarbonate Ion meterPacking list

SKU
NB020952
pHCO3 value
(2.00~4.40)pHCO3
HCO3 concentration value
2mg/L~0.6g/L
mV range
-1800~1800mV
Resolution
0.01 p HCO3
Electronic unit intrinsic error
± 0.02pHCO3 ± 1 word
Instrument intrinsic error
±0.05pHCO3
Calculation Error of Conversion of pHCO3 Value~ [HCO3] Concentration Value
± 0.3% (reading)
Instrument Repeatability Error
Not more than ± 0.03pHCO3 ± 1 word
Temperature compensation range of tested solution
(5.0~ 50.0)℃
Electronic unit stability
±0.1pHCO3/3h
PXS-HCO3
Bicarbonate Ion meter
Qiwei PXS-HCO3 Bicarbonate Ion meter Picture

Features

  1. This instrument is used to measure the concentration of bicarbonate ions dissolved in water.

  2. The instrument has manual temperature compensation and automatic temperature compensation functions (when the temperature electrode is connected, the instrument enters automatic temperature compensation and displays the current temperature; when the temperature electrode is not connected, the instrument enters manual temperature compensation, and the instrument displays the manual temperature setting value. Temperature Electrodes belong to the selection key. If the user requires it, it should be shown when ordering.

  3. In addition to displaying the pF value, the instrument also displays the calcium ion concentration value [Ca].

  4. The instrument is both beautiful and light.

Qiwei PXS-CL Chloride Concentration Meter


FAQ
QCan the concentration of carbonic acid in field water be measured directly?
A This one is OK. Different ion meters are designed for the measurement of each ion content in aqueous solutions, especially for the quality monitoring of high-purity water in power plants (such as steam, condensate, boiler feed water, etc.), and can also be used in institutions of higher learning, scientific research structures, Petrochemicals, microelectronics and other departments to determine the corresponding Ion concentration (or activity) in natural water, industrial drainage and other water.
QDo you have the carbonic acid ion meter required by JB/T6858 standard?
A This PXS-HCO3 carbonic acid ion meter will do.
Standard