China

KSJ MG6-F2 intelligent Gloss meter, projection angle 60 °

SE
60 degree measurement, including haze and reflectance measurement, MG6-F2 boot self-calibration and self-diagnosis, 10,000 measurement data storage capacity, support for deleting data, standard Gloss data processing software.
Model:
Certificate

KSJ MG6-F2 Intelligent Gloss MeterSPEC

KSJ MG6-F2 Intelligent Gloss MeterDetails

KSJ MG6-F2 Intelligent Gloss MeterPacking list

SKU
NB002158
Geometry
60°/85°
Measurement range
0~1000GU
Repeatability
0.2GU;0.2%
Reproducibility
0.5GU|0.5%
Measuring Areas
9*16mm
Error of indication
±1.5; ±1.5%GU
Division Value
0.1GU|1GU
Standards
ASTM D523、GB/T13891、GB7706、GB8807、JJG 696-2002
Dimensions
155*48*75mm
Weight
400g
Power
One AA (or LR6) alkalinity dry or rechargeable battery
Measurement port size
12*28mm
Zero Error
0.2GU
Operating Time
One alkalinity dry battery can support more than 20,000 measurements
MG6-F2
Intelligent Gloss Meter
60 degree measurement, including haze and reflectance measurement, MG6-F2 boot self-calibration and self-diagnosis, 10,000 measurement data storage capacity, support for deleting data, standard Gloss data processing software.
KSJ MG6-F2 intelligent Gloss meter, projection angle 60 ° Picture

product description

KSJ MG6-F2 intelligent gloss meter is a gloss measuring instrument designed and manufactured according to the international standard ISO2813 and Chinese national standard GB/T9754. The Specifications of the intelligent gloss meter meet the requirements of ASTM D523, GB/T13891, GB7706, and GB8807 standards. All performance indicators meet the requirements of the first-class working machine in the national JJG 696-2002 "Specular Gloss Meter and Gloss Board" metrological verification regulations.

The gloss value of the intelligent gloss meter can be traced back to the national glossiness benchmark of Shanghai Institute of Metrology and Testing Technology (SIMT).

The main function

  • Multi-angle one-key to complete the measurement

  • Optional angle mode

  • Power-on self-diagnosis, self-calibration

  • Practical and rich display interface: Simultaneously display each current measurement value, average value, group sequence number and measurement sequence number

  • The measurement data is pre-grouped, and each measurement group can contain a maximum of 99 measurements

  • The unit of measurement defaults to Gloss Units (GU), and can also be switched to Percent Reflectance (%)

  • Grouped measurement data can be browsed by specifying the group number

  • Immediate deletion of invalid measurements

  • Comes with USB adapter and Glossy data processing software

  • It has the functions of low power prompt and full storage prompt

Application

MG6-F2 intelligent gloss meter is widely used in materials and products in many fields such as paint coatings, decoration materials, building materials, plastic materials, bamboo and wood products, ceramic products, leather products, film paper, printing ink, automobile maintenance, molding molds, etc. Gloss measurement of surfaces.

structure diagram

KSJ MG6-F2 intelligent gloss meter is the front structure diagram

KSJ MG6-F2 intelligent gloss meter back structure diagram

Structural diagram of KSJ MG6-F2 intelligent gloss meter working board

Structural diagram of the battery compartment of KSJ MG6-F2 intelligent gloss meter

Structural diagram of KSJ MG6-F2 intelligent gloss meter calibration work board

plan

KSJ MG6-F2 Intelligent Gloss Meter Appearance Figure 1

KSJ MG6-F2 Intelligent Gloss Meter Appearance Figure 2

KSJ MG6-F2 Intelligent Gloss Meter Test Chart 1

KSJ MG6-F2 Intelligent Gloss Meter Details

FAQ
QCan you measure the average value?
A All four models of the F2 smart series can be automatically averaged.
QCan KSJ's glossmeter measure the average?
A Yes, all four models of the F2 Smart Series can be automatically averaged.
QWhat is the difference between the MG6-F1 and MG6-F2 glossmeters?
A The MG6-F2 not only measures Gloss, but also haze and reflectance.
QIt is used to measure the surface Glossiness of anti-corrosion coatings. Can it be measured with this one?
A Sure
QDoes the KSJ glossmeter have data processing software?
A Hello, yes.
QWhat is the error of the MG6-F1 Gloss meter?
A Hello, the error is ± 1.2GU.
QCan this Gloss meter from Keshijia detect the Gloss of paper?
A Hello, it's OK.
QWhat is the error of this gloss instrument?
A Hello, it's 0.2GU.
QWill the strong light environment affect the measurement of glossmeters? How to solve?
A Strong light environment will affect the measurement of glossmeter, it is recommended to avoid strong light environment measurement, if you want to avoid external light leakage, you can use black flannel around the measuring port to block the rays of light.
QWhat is the difference between WGG60 series and MG series Glossiness?
A WGG60 series host power supply is built-in rechargeable lithium battery. MG series host power supply is an AA (No. 5) rechargeable or alkaline battery. If the use Frequency is high, use WGG60 series. On the contrary, if the use Frequency is low, use MG series, but please take out the battery after use to protect the instrument host.
Knowledge
Standard