Netherlands

TQC VF9700 MFFT20 minimum film forming temperature (MFFT) Tester -30~ + 250 ℃

SE
The TQC MFFT 20 minimum film forming temperature (MFFT) meter VF9700 Operating temperature is -30~ + 250 ℃, the temperature layer MAX Maximum is 100K, the MFFT 20 minimum film forming temperature (MFFT) meter lid is suitable for temperatures up to + 250 ℃.
$60310.00/set
PromotionLoading...
Coupon
Model:
Certificate

TQC sheen VF9700 Minimum film forming temperature (MFFT) TesterSPEC

TQC sheen VF9700 Minimum film forming temperature (MFFT) TesterDetails

TQC sheen VF9700 Minimum film forming temperature (MFFT) TesterPacking list

SKU
NB022291
Layered plate Operating temperature range
-30~250℃
Temperature measurement point
20 point
Temperature layer
MAX Maximum 100 K
Dimensions
800*350*320mm
Test strip size
500x180mm
Power supply Voltage
230V,50Hz,1.5KW
Weight
50kg
VF9700
Minimum film forming temperature (MFFT) Tester
TQC VF9700 MFFT20 minimum film forming temperature (MFFT) Tester -30~ + 250 ℃ Picture

Introduction

Temperature gradient plates are used to determine the minimum film-forming temperature test.

The minimum film-forming temperature is the lowest temperature at which an emulsion, latex, or adhesive coalesces uniformly when applied to the substrate as a film.

Knowing the MFFT temperature allows formulators to create products that cure correctly under the desired application conditions. The instrument can also be used to define white point/glass transition temperatures for dispersed materials, synthetic resins, enamels, etc., as well as blocking and stacking capabilities for coated paper, foils, prints......

The TQC MFFT TEST is a precision test instrument with a metal platen of ground hard chrome for the deposition of samples. By heating and cooling the platen, any variable temperature gradient in the range of -30 to +250°C can be created and remains constant for any given time. The platen is equipped with 10 or 20 evenly spaced temperature sensors. The temperature is controlled via an integrated digital controller, with a digital display and measuring point selector covering the entire range. To define an MFFT, the sample should be applied to the platen using a Film Applicator and protected from environmental conditions by a transparent cover. Creates a stream of dry air to prevent condensation and ensure repeatability. To determine the blocking capacity, the specimen on the platen is weighed with a defined load to simulate the stacking capacity. The TQC MFFT TEST complies with the following standards: acc.

Meets standards

DIN ISO 2115 - DIN 53366 - ASTM D 2354 - ASTM D 1465 - ISO 2115 - ISO / DIS 4622.

Product display

Showing of the Dutch TQC MFFT 20 minimum film forming temperature Tester VF9700